11
Mode 4: Free standing unidirectional
In this mode, one SentryHound-Pro unit can be used for foot
traffic passing by only one side of the unit. Be sure that unit is
placed on solid, level flooring (preferably concrete or tile) with
no give or else it might falsely trigger. Once powered on, even
small amounts of ferrous material passing within 18 to 32
inches from the pole and from ground level up to 75 inches
above the ground, will trigger an alert. The unit can only trigger
while someone is moving past the sensors meaning security
staff can move freely around the portal without triggering any
alert.
The alert LEDs on one side of the poles, the buttons and the
SentryHound-Pro etching on the base should all be viewable
and easily accessible for security personnel while foot traffic should only move on the opposite side of the unit.
Hold the POWER + CALIB ALERT buttons while powering up to enter this mode. The ALERT
button will then blink 5 times to indicate that this mode has been entered. Remember that even after powering
off and on again, this mode will still be active unless you return to the factory defaults by holding down
POWER + ALERT buttons while powering on unit.
Note: If ferrous material passes by the unit at the same time that someone else moves near the portal, there is a
risk of false detection. SentryHound-Pro should always be setup in an area with minimal ferromagnetic activity.
This activity can include large moving ferrous objects such as wheeled office chairs, filing cabinet drawers,
steel doors and even large trucks in a nearby parking lot.