background image

 

 

 
 
 
 
 
 
 
 
 
 
 

 

SentryHound-Pro Ferromagnetic Portal  

User Manual Version 1.5 

 

 

Содержание SentryHound-Pro

Страница 1: ...SentryHound Pro Ferromagnetic Portal User Manual Version 1 5...

Страница 2: ...ore About Ferrous Detection 7 Operational Modes 8 Free Standing Gated Tethered Portal 8 Free Standing Gated Untethered Portal 9 Wall Mounted Unidirectional 10 Free Standing Unidirectional 11 Free Stan...

Страница 3: ...c Contraband Portal 2 poles included for the quickest most accurate ferromagnetic inspection security checkpoint Single pole setup anywhere in under 30 seconds Lightweight versatile all day battery po...

Страница 4: ...d to move it into an area where there are no nearby power outlets It can take several hours to fully charge When you first power the unit on it will automatically enter into a calibration procedure ta...

Страница 5: ...ging the internal battery The rear side of the base includes a motion sensor just like on the other side of the base and also an infrared sensor for communication between two pole configurations This...

Страница 6: ...ferrous material Red LED alert zone clusters in sensor pole stay solid to indicate area of ferrous detection Solid yellow indicates calibration in progress Allow the unit to fully calibrate about 30...

Страница 7: ...tion sensitivity The higher the sensitivity setting more LEDs lit on the pole the more the unit is prone to false triggers ALERT Push this button to cycle through various alert audio and visual durati...

Страница 8: ...t the sensor with the strangest signal will be visually indicated Please note that the following items not exhaustive list might have enough ferrous material to trigger a ferrous detector rolling offi...

Страница 9: ...nches above the ground will trigger an alert Poles will only trigger while someone is moving between them meaning security staff can move freely around the portal without triggering any alert Setting...

Страница 10: ...curity staff can move freely around the portal without triggering any alert Since this configuration does not require any tethering units may be powered on at any time and do not need to be facing in...

Страница 11: ...d wall bracket Be sure the unit is mounted on solid wall as low as possible toward the floor otherwise contraband could be slip by the sensors undetected Once the units are powered on even small amoun...

Страница 12: ...ould all be viewable and easily accessible for security personnel while foot traffic should only move on the opposite side of the unit Hold the POWER CALIBRATION ALERT buttons while powering up to ent...

Страница 13: ...buttons while powering up to enter this mode The ALERT button will then blink 4 times to indicate that this mode has been entered Remember that even after powering off and on again this mode will stil...

Страница 14: ...ound will trigger an alert When the unit is powered on the ALERT button will blink once to indicate this default mode If it does not behave this way you can return to the factory defaults by holding d...

Страница 15: ...spond to the detection range For instance a sensitivity setting of 2 might not detect a smartphone that is 27 inches from the nearest sensor but a sensitivity setting of 6 would stand a better chance...

Страница 16: ...urrent alert settings After 3 seconds the alert display will stop but if you push the ALERT button before that it will increment to the next setting each time you push the button Setting 1 Setting 2 S...

Страница 17: ...or over 24 hours Battery power can be checked at any time by pressing the BATTERY button The LED clusters on the sensor pole will display for 3 seconds the remaining battery power in 25 increments Whe...

Страница 18: ...17...

Страница 19: ...am Customer Support Berkeley Varitronics Systems Inc Liberty Corporate Park 255 Liberty Street Metuchen NJ 08840 8 00 AM to 6 00 PM EST Toll Free 888 737 4287 Phone 732 548 3737 Fax 732 548 3404 24 7...

Отзывы: