• Unfasten hardware holding packing gland in place and slide
back on shaft to expose packing rings. A split packing gland
with threaded studs is shown.
• Remove packing rings from stuffing box using two com-
mercially available packing hooks as shown.
• Slide lantern ring (if used) back to expose any remaining
rings, including metallic. Remove them in the same manner.
F00636
Page 17
Packing Ring Replacement
Maintenance
Removal
Packing
Gland
Packing
Hooks
Packing
Ring
Shaft
Shaft
6052 0609
Pump liquid end removed
for
pictorial clarity
only.
1
2
Packing
Gland
Shaft
BERKELEY
Pump liquid end and packing
insert removed for
pictorial
clarity
only
. Remove packing
gland and packing rings through
frame cutout.
Metallic
Ring
Lantern Ring
(stays on shaft)
Stagger ring
joints 90 degrees
apart.
Packing
Rings
Typical Packing
Arrangement
Pump liquid end removed
for
pictorial clarity
only
.
Remove packing gland and
packing rings through frame
cutout.
6053 0609
Installing New Rings
• Clean shaft sleeve and packing gland.
• Inspect shaft sleeve for wear, replace if needed.
• Install new packing rings in stuffing box by placing over
shaft sleeve and pushing them in as far as they will go.
• Rotate ring joint 90 degrees when installing each ring as
shown.
• Slide packing gland into position (gland must enter stuffing
box bore) then gently and evenly tighten nuts to force rings
into place and seat (do not over tighten). Loosen nuts again
to hand tight.
• Start primed pump and allow packing to leak liberally.
• While pump is running, evenly tighten gland nuts one
complete turn at a time until leakage is reduced to droplet
form (40 to 60 drops per minute).
See Page 19 for Seal Replacement.