background image

8

REPLACEMENT PARTS LIST

* Standard hardware item, purchase locally.

Key

No.

Description

Qty.

10PDH11VT

15PDH11VT

1

Motor

1 A100EL-T

A100FL-T

2

Slinger

1

17351-0009

17351-0009

3

Priming plug

1

WC78-39T

WC78-39T

4

Seal plate

1

L176-47P1SS

L176-47P1SS

5

O-Ring  

1

U9-424

U9-424

6

Shaft seal

1

U109-196SS

U109-196SS

7

Impeller

1

C105-92PVH

C105-92PBS

8

Diffuser

1

C1-258PCASS

C1-258PCASS

9

#8-32 x 1” Screw, stainless steel 

3

*

*

10

Clamp

1

C19-54SS

C19-54SS

11

Pump body

1

C176-66P

C176-66P

12

1/4” NPT Drain plug 

1

WC78-40T

WC78-40T

13

Diffuser O-Ring

1

U9-425

U9-425

14

Base

1

C4-41P

C4-41P

15

5/16 Washer, stainless steel

4

*

*

16

5/16 - 18 Nut, stainless steel

4

*

*

17

Motor pad

1

C35-15

C35-15

MODELS

10PDH11VT, 15PDH11VT

L17

6-35P

1

2

4

5

6

8

9

10

11

12

13

14

15

16

17

7

3

Содержание 10PDH11VT

Страница 1: ...missing or damaged safety labels Make workshops childproof use padlocks and master switches remove starter keys Electrical Safety Hazardous voltage Can shock burn or cause death Ground pump before con...

Страница 2: ...and scale Foreign matter will plug pump and void warranty Use new pipe for best results 3 Protect pump and all piping from freezing Freezing will split pipe damage pump and void warranty Check locall...

Страница 3: ...tank are required For proper installation and operation instructions call Customer Service Use rigid pipe Do not use hose or plastic tubing See Well Pipe Installation for more information NOTE Use onl...

Страница 4: ...protection while working on motor For switch requirements consult your local building inspector for information about codes 3 Disconnect power before servicing motor or pump If the disconnect switch i...

Страница 5: ...purchased separately will help monitor pressure so that it is not allowed to exceed maximum pumping pressures according to performance chart To prevent explosion do the following 1 Be sure discharge...

Страница 6: ...ity in seal plate See Figure13 Polished face of ceramic seat is up If seal will not seat correctly remove placing seal face up on bench Reclean cavity Seal should now seat correctly 3 If seal does not...

Страница 7: ...ction line into water and re prime If receding water level in well pipe inlet well pump is needed Impeller is plugged Clean impeller Check valve or foot valve is Replace check valve or foot valve stuc...

Страница 8: ...ft seal 1 U109 196SS U109 196SS 7 Impeller 1 C105 92PVH C105 92PBS 8 Diffuser 1 C1 258PCASS C1 258PCASS 9 8 32 x 1 Screw stainless steel 3 10 Clamp 1 C19 54SS C19 54SS 11 Pump body 1 C176 66P C176 66P...

Страница 9: ...as possible after the discovery of any alleged defect Berkeley Wicor will subsequently take cor rective action as promptly as reasonably possible No requests for service under this warranty will be ac...

Отзывы: