OPTIPAC SYSTEM FUNCTIONS
Main Menu
OptiPac 6611MD User's Manual
15
Main Menu
The default display on the front panel LCD is the time/date. When the
SELECT
button is pressed, the first choice of the Main menu will be
displayed. You can scroll the Main menu by repeatedly pressing the
SELECT
button. To execute the selected function or to enter the sub-
menu, press the
ENTER
button. The time/date display will look appear
similar to the following display when the system is first powered on
and when the unit is on-line:
4:15:12PM
10/12
Ring 04
LABEL
If a ring has a label, it will be displayed after the ring number. All ring
numbers on the hard drive begin with the letter H (H04), while all rings
on the removable cartridge have just a numeral (04).
Note:
Attempting to perform any function on a new and/or unformatted
cartridge may cause the following message to display:
Media not
initialized!
The cartridge must be formatted from the Removable Utilities menu
before it can be used.
The following options are available from the Main menu of the OptiPac:
Change ring
Unload cartridge
Configurations
Utilities
Display time and messages
Change Ring
This function allows you to change the current ring. When you return
to the main menu the current ring will be displayed. Rings that begin
with ‘H’ indicate a ring on the hard disk. Ring H000 emulates the hard
disk in a 7906M and cannot be accessed from the front panel LCD
controls. All other rings emulate removable disks.
1. Press the
SELECT
button until the
Change ring
function is displayed on
the Main menu.
2. Press
ENTER
to select this option.
3. Use the
SELECT
button to scroll through the ring selections until you
see the desired ring, then press the
ENTER
button.