Start-up
Operating manual, Dumper – 3012 PLUS
105
- 131
28 April 2015
Bergmann Maschinenbau GmbH & Co. KG
10.4.
Heating up hydraulic system
At ambient temperatures below
0°C
, let the hydraulic system of the dumper warm up for a few minutes by
operating the trough tilt cylinder to the stop.
10.5.
Shutting down diesel engine
After heavy-duty work, let the engine run at idle speed for 1 to 2
minutes! Only then shut it down!
Set the travel direction switch to zero position.
Turn the ignition key to position "
0
".
Remove the ignition key.
Apply the parking brake by actuating the switch (button).
CAUTION