Start-up
Operating manual, Dumper – 3012 PLUS
101
- 131
28 April 2015
Bergmann Maschinenbau GmbH & Co. KG
10.1.
Checks to be performed prior to start-up
Before starting the dumper, carry out the safety checks below:
Inspect all components that are accessible to the driver for wear, deformation, corrosion, damage and
proper fixture. Inspect hose lines for leakage and damage.
10.1.1. Oil level in engine
Place the dumper on horizontal ground. The oil level must be between the 2 marks on the dipstick. For
details, see maintenance instructions, section 9.2.1.2.
10.1.2. Fuel tank
Read the fuel level on the diesel tank level gauge. For details, see maintenance instructions, section
9.4.1.2.
10.1.3. Fluid level in hydraulic fluid tank
Place the dumper on horizontal ground. The hydraulic fluid level must be between the 2 marks of the
sight glass. For details, see maintenance instructions, section 8.1.1.2.