23
step in charging current rather than sev-
eral smaller ones.
•
Setting high voltage regulation points too
low so that the batteries don’t get fully
charged
•
Setting the low voltage disconnect (typi-
cally part of the inverter) too high so that
the battery bank capacity is underutilized