8. SHUTDOWN CONDITIONS
Shut-down condition
Specification
Unit
Comment
Inverter
Overtemperature
Inverter tempera-
ture
≥ 65°C
°C
No AC output, wait
until temperature
drops
Overload
> 1000 (PS 1000)
> 1500 (PS 1500)
W
No AC output, discon-
nect load and restart
AC output circuit
W
No AC output, discon-
nect load and restart
Note:
If the AC output has switched off due to one of the above conditions, disconnect the
load, switch off the AC switch and switch it on again.
DC controller
USB Overcurrent
3
A
No DC output
12V DC overcurrent protection
at the output
15
A
No DC output
Solar charging, protection,
voltage cut-off
29,2 – 29,7
V
Disconnects the charge
after reaching the
voltage
Battery
Overcharge protection for one
cell; Voltage protection
4,2 per cell
V
Separates the charge
Deep discharge protection
2,8 per cell
V
Output will be swit-
ched off
Batterypack Overtemperature
protection
≥ 65
°C
Input and output are
switched off
Short circuit protection
Ja
Output is switched off
after short circuit
Overcurrent protection for the
battery pack
120 – 180
A
Output is switched off
after overcurrent