20
Chapter 7 Battery Status
IR518C thermal imager is power supplied by 2 units of replaceable and rechargeable Ni-MH AA
batteries, average operation time is 2 hours.
7.1 Battery charging method:
1) Aim the batteries electrode to the charger’s electrode, and insert the battery into the charger.
Please pay attention to the inserting direction and position
2) Insert the 100-240VAC/9VDC adaptor plug into the AC charge socket. Connect the AC adaptor
cable to the 100
~
240VAC socket to start charging
3) When start the charging, the red and blue indicator will flicker alternatively.
4) In the process of charging, the red indicator is lightening, when fully charged, the blue indicator is
lightening.
5) It’s normal that the AC adaptor will get heat during the charging process.
If the
IR518C
meets troubles please check the items listed below first, if the troubles beyond those
ones please contact us as soon as possible.
No.
Trouble
Reason/Measure
1
The Thermal Imager can
No battery or lack of power; remove battery an install a fully
not be turned on
charged on.
Battery bad connection; reinstall the battery and tighten the
battery cover.
Switch off the system, and reboot it after 20 seconds.
2
The image is blurry
Adjust focus till image clear.
3
The image is too dark
Perform NUC function manually.
or too bbright
Adjust brightness and contrast manually or set to auto
brightness/contrast mode.
4
No image output
Display equipment connection problem or video cable
connection problems