PRESSIONE IMPIANTO INSUFFICIENTE (T)
E 41
TRASDUTTORE PRESSIONE ACQUA (D)
E 42
SCHEDA ELETTRONICA (D)
E 50-59
SONDA SANITARIO 1 (T)
E 60
SONDA PRIMARIO (T)
E 71
TERMOSTATO BASSA TEMPERATURA (T)
E 77
EXCLUSIVE GREEN - MICROGREEN - BOILER GREEN
BLOCCO MANCANZA FIAMMA (D)
E 10
FIAMMA PARASSITA (T)
E 11
RITENTATIVO ACCENSIONE (T)
E 12
PRESSIONE MINIMA INGRESSO GAS (T)
E 13
PRESSIONE MINIMA INGRESSO GAS (D)
E 14
FIAMMA PRESENTE SENZA RAGIONE IN STAND-BY (D)
E 15
TERMOSTATO LIMITE/TERMOSTATO BRUCIATORE
E 20
SONDA FUMI CORTO CIRCUITO (D)
E 21
SONDA FUMI MASSIMA TEMPERATURA (D)
E 22
SONDA MANDATA TEMPERATURA LIMITE (D)
E 24
SONDA MANDATA TEMPERATURA LIMITE (T)
E 25
SONDA RITORNO TEMPERATURA LIMITE (D)
E 26
SONDA RITORNO TEMPERATURA LIMITE (T)
E 27
DIFFERENZIALE SONDA RITORNO-MANDATA (D)
E 28
SONDA FUMI CIRCUITO APERTO (D)
E 29
SCARICO FUMI O PRESSOSTATO ARIA (inizio ciclo) (D)
E 30
SCARICO FUMI O PRESSOSTATO ARIA (in ciclo) (T)
E 31
VENTILATORE IN CICLO (basso numero di giri) (D)
E 33
VENTILATORE (inizio ciclo) (D)
E 34
VENTILATORE (fine ciclo) (T)
E 35
SCARICO FUMI O PRESSOSTATO ARIA (in ciclo) (T)
E 36
VENTILATORE IN CICLO (alto numero di giri) (D)
E 37
SCARICO FUMI O PRESSOSTATO ARIA (in ciclo) (D)
E 38
PRESSIONE IMPIANTO INSUFFICIENTE (D)
E 40
PRESSIONE IMPIANTO INSUFFICIENTE (T)
E 41
TRASDUTTORE PRESSIONE ACQUA (D)
E 42
CICLO DI SFIATO (BOILER GREEN)
E 43
SCHEDA ELETTRONICA (D)
E 50-59
SONDA SANITARIO 1 (GREEN R.S.I. solo con bollitore con sonda) (T)
E 60
ANOMALIA CICLO MINIACCUMULO (MICROGREEN) (T)
E 65
SONDA PRIMARIO CORTO CIRCUITO/APERTA (D)
E 70
SONDA MANDATA SOVRATEMPERATURA (T)
E 71
SONDA RITORNO CORTO CIRCUITO/APERTA (D)
E 72
TERMOSTATO BASSA TEMPERATURA (T)
E 77
DIFFERENZIALE MANDATA/RITORNO (T)
E 78
DIFFERENZIALE MANDATA/RITORNO (D)
E 79
ANOMALIA DI SISTEMA (D)
E 80
ANOMALIA DI SISTEMA (T)
E 81
ANOMALIA DI SISTEMA (D)
E 82
ANOMALIA DI SISTEMA (T)
E 83
CONDENSA O SENSORE DI CONDENSA (D)
E 92
CONDENSA O SENSORE DI CONDENSA (T)
E 93
SENSORE DI CONDENSA O CIRCUITO APERTO (D)
E 94
SENSORE DI CONDENSA O CIRCUITO APERTO (T)
E 95
D = definitivo
T = temporaneo
FAULT DESCRIPTION
fault code
EXCLUSIVE - EXCLUSIVE SINTHESI
FLAME FAILURE BLOCK (D)
E 10
PARASITE FLAME (D)
E 11
LIMIT THERMOSTAT (D)
E 20
BURNER THERMOSTAT (D) (MIX C.S.I. - R.S.I. - SINTHESI C.S.I.)
E 21
FUMES THERMOSTAT (D) (C.A.I. - R.A.I.)
E 22
FUMES OUTLET OR AIR PRESSURE SWITCH (cycle start) (D) (MIX C.S.I.-R.S.I.-SINTHESI)
E 30
FUMES OUTLET OR AIR PRESSURE SWITCH (in cycle) (T) (MIX C.S.I.-R.S.I.-SINTHESI)
E 31
INSUFFICIENT INSTALLATION PRESSURE (D)
E 40
INSUFFICIENT INSTALLATION PRESSURE (T)
E 41
WATER PRESSURE TRANSDUCER (D)
E 42
ELECTRONIC BOARD (D)
E 50-59
SANITARY PROBE 1 (T) (R.A.I.-R.S.I. only with water tank with probe)
E 60
MINITANK CYCLE FAULT (T) (MICROCAI - MICROMIX)
E65