31
ENGLISH
PARAMETERS
UM
MYNUTE X R
METHANE GAS (G20)
LPG (G31)
Lower Wobbe index (at 15°C-1013 mbar)
MJ/m³S
45,67
70,69
Net Calorific Value
MJ/m³S
34,02
88
Supply nominal pressure
mbar (mm H2O)
20 (203,9)
37 (377,3)
Minimum supply pressure
mbar (mm H2O)
10 (102,0)
-
20 R
Burner: diameter/length
mm
70/86
70/86
Diaphragm: holes number - holes diameter
n° - mm
1 - 4,3
1 - 4,3
CH maximum gas capacity
Sm³/h
2,12
-
kg/h
-
1,55
DHW maximum gas capacity
Sm³/h
2,12
-
kg/h
-
1,55
CH minimum gas capacity
Sm³/h
0,38
-
kg/h
-
0,39
DHW minimum gas capacity
Sm³/h
0,38
-
kg/h
-
0,39
Number of fan rotations with slow ignition
rpm
5.500
5.500
Maximum number of CH fan rotations
rpm
6.200
6.000
Maximum number of DHW fan rotations
rpm
6.200
6.000
Minimum number of CH/DHW fan rotations
rpm
1.600
2.000
Max n° of CH/DHW fan rotations in C(10) configuration (Ø60-100 ● Ø80-125 ● Ø80)
rpm
6.200
-
Min n° of CH/DHW fan revolutions in C(10) configuration (Ø60-100 ● Ø80-125 ● Ø80)
rpm
1.600
-
30 R
Burner: diameter/length
mm
70/125
70/125
Diaphragm: holes number - holes diameter
n° - mm
1 - 5,2
1 - 5,2
CH maximum gas capacity
Sm³/h
3,17
-
kg/h
-
2,33
DHW maximum gas capacity
Sm³/h
3,66
-
kg/h
-
2,69
CH minimum gas capacity
Sm³/h
0,52
-
kg/h
-
0,54
DHW minimum gas capacity
Sm³/h
0,52
-
kg/h
-
0,54
Number of fan rotations with slow ignition
rpm
5.500
5.500
Maximum number of CH fan rotations
rpm
6.900
6.900
Maximum number of DHW fan rotations
rpm
7.800
7.800
Minimum number of CH/DHW fan rotations
rpm
1.700
1.900
Max n° of CH fan rotations in C(10) configuration (Ø60-100 ● Ø80-125 ● Ø80)
rpm
6.900
-
Max n° of DHW fan rotations in C(10) configuration (Ø60-100)
rpm
8.200
-
Max n° of DHW fan rotations in C(10) configuration (Ø80-125 ● Ø80)
rpm
7.800
-
Min n° of CH/DHW fan revolutions in C(10) configuration (Ø60-100)
rpm
1.800
-
Min n° of CH/DHW fan revolutions in C(10) configuration (Ø80-125 ● Ø80)
rpm
1.700
-
40 R
Burner: diameter/length
mm
70/125
70/125
Diaphragm: holes number - holes diameter
n° - mm
1 - 5,2
1 - 5,2
CH maximum gas capacity
Sm³/h
3,17
-
kg/h
-
2,33
DHW maximum gas capacity
Sm³/h
4,23
-
kg/h
-
3,11
CH minimum gas capacity
Sm³/h
0,52
-
kg/h
-
0,54
DHW minimum gas capacity
Sm³/h
0,52
-
kg/h
-
0,54
Number of fan rotations with slow ignition
rpm
5.500
5.500
Maximum number of CH fan rotations
rpm
6.900
6.900
Maximum number of DHW fan rotations
rpm
9.100
8.900
Minimum number of CH/DHW fan rotations
rpm
1.700
1.900
b
DHW functions refer only if a water tank is connected (accessory available on request)