MYNUTE X R
SETTINGS MENU TREE STRUCTURE
Below is a list of the parameters that can be programmed; if the adjustment board does not support the relative function, the interface returns an error message:
The remote control has the function of a machine interface, displaying the system settings and providing access to the parameters.
The water tank delivery temperature is normally shown on the display (in case of water tank with probe - optional) unless a heating heat request is in progress, in this case the delivery
temperature of the boiler is displayed; after 10 seconds that no key is touched the interface displays the current time (backlight off).
The configuration MENU is organised with a multi-level tree structure. An access level has been fixed for each sub-menu: USER level always available; TECHNICAL level password pro
-
tected. Below is a summary of the SETTINGS MENU tree structure.
Some of the information might not be available depending on the access level, the status of the machine or the system configuration.
Menu
Parameter
Value
Level
password
Value set
in the factory
Personalised
values
SETTINGS
TIME
USER
TIME PROGRAMM
USER
COMB
GAS TYPE
0 / 1
INSTALLER
0
BOYLER TYPE
1 / 2 / 3 / 4
SERVICE
1 (20 kW)
3 (30 kW)
4 (40 kW)
COMBUSTION OFFSET
0 / 1 / 2
SERVICE
CONF
HYDRAULIC CONFIGURATION
0 / 1 / 2 / 3 / 4
INSTALLER
4(*)
WATER TRANSDUCER
0 / 1
SERVICE
1
AUTO WATER FILL ENABLE
0 / 1
SERVICE
0
BEGIN SYSTEM FILLING
NOT AVAILABLE ON THIS MODEL
AIR PURGING CYCLE
0 / 1
SERVICE
1
MIN
INSTALLER
see technical data
table
MAX
INSTALLER
see technical data
table
MAX_CH
MIN - MAX
INSTALLER
see technical data
table
RANGE RATED
MIN - MAX_CH
INSTALLER
see technical data
table
DO_AUX1
0 / 1 / 2
INSTALLER
0
EXHAUST PROBE RESET
0 / 1
INSTALLER
0
CH
HYST ON HIGH TEMP
2 - 10
SERVICE
5
HYST OFF HIGH TEMP
2 - 10
SERVICE
5
HYST ON LOW TEMP
2 - 10
SERVICE
3
HYST OFF LOW TEMP
2 - 10
SERVICE
3
PUMP CONTROL TYPE
0 - 100
INSTALLER
85
CH POSTCIRC
NOT AVAILABLE ON THIS MODEL
LOW NOISE
NOT AVAILABLE ON THIS MODEL
SCREED HEATING
0 / 1
INSTALLER
0
ANTI CYCLE FUNCTION
0 - 20min
INSTALLER
3min
RESET CH TIMERS
0 / 1
INSTALLER
0
MAIN ZONE ACTUATION TYPE
0 / 1
INSTALLER
0
MAIN ZONE ADDR
1 - 6
INSTALLER
3
MAIN ZONE HYDRAULIC CONF
0 / 1
INSTALLER
0
MAIN ZONE TYPE
0 / 1
INSTALLER
0
MAX CH SET
AT: MIN CH SET - 80.5
BT: MIN CH SET - 45.0
INSTALLER
80.5
MIN CH SET
AT: 20 - MAX CH SET
BT: 20 - MAX CH SET
INSTALLER
20
OTR
0 (default) / 1
INSTALLER
0
(*) The boiler leaves the factory pre-configured for managing a water tank with a thermostat (parameter HYDRAULIC CONFIGURATION = 4).