29
ENGLISH
BOILER STATUS
VISUALIZADOR
RED LED
YELLOW LED
GREEN LED
TYPES OF ALARMS
Off status(OFF)
OFF
flashing
0.5 on / 3.5 off
None
Stand-by
-
flashing
0.5 on / 3.5 off
Signal
ACF alarm lockout module
A01
on
Definitive lockout
ACF electronics fault alarm
Limit thermostat alarm
A02
flashing
0.5 on / 0.5 off
Definitive lockout
Tacho fan alarm
A03
on
Definitive lockout
Water pressure switch alarm
A04
on
on
Definitive lockout
NTC domestic water fault
A06
flashing
0.5 on / 0.5 off
flashing
0.5 on / 0.5 off
Signal
NTC heating outlet fault
A07
on
Temporary stop
Heating outlet probe overtemperature
Temporary then
definitive
Outlet/return line probe differential alarm
Definitive lockout
NTC heating return line fault
A08
on
Temporary stop
Heating return line probe overtemperature
Temporary then
definitive
Outlet/return line probe differential alarm
Definitive lockout
Cleaning the primary heat exchanger
A09
flashing
0.5 on / 0.5 off
flashing
0.5 on / 0.5 off
Signal
NTC flue gases fault
Temporary stop
Flue gases probe overtemperature
on
Definitive lockout
False flame
A11
flashing
0.2 on / 0.2 off
Temporary stop
Low temperature system thermostat alarm
A77
on
Temporary stop
Temporary pending ignition
flashing
0.5 on / 0.5 off
Temporary stop
Water pressure switch intervention
flashing
0.5 on / 0.5 off
Temporary stop
Calibration service
ADJ
flashing
0.5 on / 0.5 off
flashing
0.5 on / 0.5 off
flashing
0.5 on / 0.5 off
Signal
Calibration installer
Chimney sweep
ACO
flashing
0.5 on / 0.5 off
Signal
Vent cycle
flashing
0.5 on / 1.0 off
flashing
0.5 on / 1.0 off
flashing
0.5 on / 1.0 off
Signal
Preheating active function
on
Signal
Preheating heat request
flashing
Signal
External probe presence
Signal
Domestic water heat request
60°C
Signal
Heating heat request
80°C
Signal
Antifreeze heat request
Signal
Flame present
on
Signal