background image

This manual, Code 20117340 - Rev. 6 (12/17) comprises 8 pages.

2

GENERAL INFORMATION

RANGE

MODEL

CODE

IDRA DS 200 N

20117881

IDRA DS 300 N

20117882

IDRA DS 430 N

20117883

IDRA DS 550 N

20117884

IDRA DS 750 N

20132278

IDRA DS 1000 N

20132281

ACCESSORIES

For a complete list of accessories and details of their com-

patibility, refer to the Catalogue.

Dear heating engineer,

We would like to congratulate you on having recommended 

B

 solar storage cylinder unit: a modern product that's 

capable of ensuring a high degree of reliability, efficiency, 

quality and safety.

While your technical skills and knowledge will certainly be 

more than sufficient, this booklet contains all the informa-

tion that we have deemed necessary for the device's cor-

rect and easy installation.

Thank you again, and keep up the good work,

Beretta

CONFORMITY

The 

B

 solar heaters comply with DIN 4753-3 and UNI 

EN 12897.

CONTENTS

The following symbols are used in this manual:

CAUTION! =

 Identifies actions that require caution 

and adequate preparation.

STOP! =

 Identifies actions that you MUST NOT do.

1  GENERAL SAFETY INFORMATION

Check that the product is complete, undamaged and 

as ordered as soon as you receive it. Report any dis-

crepancies or damage to the 

B

 dealer who sold it.

This product must be installed by a legally qualified 

heating engineer. On completion of the installation, 

the installer must issue the owner with a declaration 

of conformity confirming that the installation has been 

completed to the highest standards in compliance 

with the instructions provided by 

B

 in this instruc-

tion manual, and that it conforms to all applicable laws 

and standards.

This product must only be used for the purpose for 

which it is designed and made, as specified by 

B

B

 declines all responsibility, contractual or other, 

for damage to property or injury to persons or animals 

caused by improper installation, adjustment, mainte-

nance or use.

The product must be serviced at least once a year. 

Servicing must be arranged in advance with the 

B

 

Technical Assistance Centre.

All servicing and repairs must be performed by a qual-

ified heating engineer.

If water leaks from the storage cylinder, turn off the wa-

ter supply and contact 

B

’s Technical Assistance 

Centre or a qualified heating engineer immediately.

If the product is not going to be used for an extended 

period of time, contact the manufacturer’s Technical 

Assistance Centre to have at least the following oper-

ations performed:

- Close the shut-off cocks for the domestic hot water 

circuit

- Shut down the boiler connected to the storage cylin-

der as instructed in its own manual

- Switch the storage cylinder OFF at the control panel 

(if fitted) and at the mains power switch

- Drain the central heating circuit and domestic hot 

water circuit if there is any risk of freezing.

This instruction manual is an integral part of the prod-

uct. It must be kept safe and must ALWAYS accom-

pany the product, even if it is sold to another owner or 

transferred to another user or to another installation. If 

you lose this manual, order a replacement immediate-

ly. Keep the product purchase documents to be pre-

sented to the 

B

 authorised Technical Assistance 

Centre to request a service call under warranty.

Size the solar expansion tank so as to ensure complete 

absorption of the expansion of the fluid contained within 

the system, with reference to the prevailing regulations 

on the matter. In particular, consider fluid character-

istics, considerable fluctuation of service temperature 

and vapour that might be generated during solar col-

lector stagnation stage. Proper size of expansion tank 

ensures setting off of all volume changes of the heat 

transfer  fluid,  avoiding  excessive  pressure  increase. 

Limited pressure changes avoid reaching safety valve 

opening pressure and the consequent fluid drainage.

This manual, Code

- Rev.

comprises

pages.

ENGLISH

General information

GENERAL INFORMATION                                            2

General Safety Information  . . . . . . . . . . . . . . . . . 2

2 Precautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Description of the appliance  . . . . . . . . . . . . . . . . 3

Identification  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

System layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Technical specifications  . . . . . . . . . . . . . . . . . . . 4

INSTALLATION                                                              6

Unpacking the product  . . . . . . . . . . . . . . . . . . . . 6

Assembly of the insulation and the lining 

(models 750 - 1000). . . . . . . . . . . . . . . . . . . . . . . 6

Place of installation  . . . . . . . . . . . . . . . . . . . . . . . 6

10 

Installation in older systems and systems 

requiring modernisation. . . . . . . . . . . . . . . . . . . . 6

11 

Water quality requirements  . . . . . . . . . . . . . . . . . 6

12 

Water connections . . . . . . . . . . . . . . . . . . . . . . . . 7

13 

Recycling and disposal . . . . . . . . . . . . . . . . . . . . 8

END USER                                                                    8

14 Start-up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

15 

Temporary shutdown . . . . . . . . . . . . . . . . . . . . . . 8

16 

Preparing for extended periods of disuse . . . . . . 8

17 

External maintenance  . . . . . . . . . . . . . . . . . . . . . 8

Содержание IDRA DS 200 N

Страница 1: ...Installation and Operation Manual IDRA DS 200 300 430 550 N IDRA DS 750 1000 N Solar solar storage cylinder IDRA DS N Installation and Operation Manual EN...

Страница 2: ...eaks from the storage cylinder turn off the wa ter supply and contact B s Technical Assistance Centre or a qualified heating engineer immediately b If the product is not going to be used for an extend...

Страница 3: ...ange is provided for easy cleaning and mainte nance of the anti corrosion magnesium anode 4 IDENTIFICATION The B IDRA DS N solar heaters can be identified by Data plate This lists the technical specif...

Страница 4: ...cording to UNI 11300 1 38 1 53 1 67 1 89 2 13 2 33 W K Energy class B B B B B B PERFORMANCE RELATING TO INTEGRATION COIL Upper coil continuous efficiency ACS 10 45 C Vbu reference volume Upper coil de...

Страница 5: ...heater pre heated to the indicated temperature considering an increase of the domestic water temperature of 30 C between inlet and outlet according to EN 12897 Temperature of accumulation tank lower...

Страница 6: ...h open Apply the upper insulation 2 and the upper cover 5 in order to insert the cover exert a light and ho mogeneous pressure Close the interlocking flaps L completely which were previously left with...

Страница 7: ...348 289 289 mm C 403 393 427 443 428 421 mm D 598 693 684 788 799 834 mm E 738 903 824 1088 969 1006 mm F 878 1113 964 1328 1144 1337 mm G 953 1233 1064 1428 1234 1426 mm H 1029 1323 1174 1538 1321 15...

Страница 8: ...uit are all open Switch the electricity supply ON at the mains power switch and at control panel switch if fitted 15 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of...

Отзывы: