GENERAL INFORMATION
7
EMPTYING IN 10’
IDRA DS FI
200
300
430
550
PERFORMANCE RELATING TO INTEGRATION COIL
Quantity of domestic water obtained in 10’ with heater pre-heated to 60°C (*) and primary exchanger at the in-
dicated delivery temperature, considering an increase of the domestic water temperature of 30°C between inlet
and outlet (according to EN 12897).
Upper coil delivery temperature
80°C
166
260
330
345
l
70°C
138
255
323
340
l
60°C
131
250
308
336
l
PERFORMANCE RELATING TO SOLAR COIL
Quantity of domestic water obtained in 10’ with heater pre-heated to the indicated temperature (**) considering
an increase of the domestic water temperature of 30°C between inlet and outlet (according to EN 12897).
Temperature of accumulation tank lower part
70°C
374
438
659
863
l
60°C
284
375
531
675
l
50°C
205
310
390
485
l
DESCRIPTION
SOLAR STATION TECHNICAL DATA
Safety valve calibration pressure
6
bar
Maximum operating temperature
110
°C
Power supply
230~50
V-Hz
Min/max electrical current draw
0,08 ÷ 0,58
A
Min/Max power consumption
5 ÷ 63
W
Pressure drops
TOP COIL
PRESSURE DROP (mbar)
400
300
200
500
100
0
0
1000
2000
3000
4000
300
200
430
550
FLOW RATE (l/h)
Useful head available
BOTTOM COIL
USEFUL HEAD AVAILABLE (mbar)
700
650
600
0
400
200
300
500
100
700
650
550
450
500
600
400
350
300
0
400 600 800 1000
200
1200 1400
200
300
430
550
200
300
430
550
FLOW RATE (l/h)
Values referred to a mix of water and 30% glycol.
The circulator speed is controlled through PWM signal and
varies according to the thermal gradient between solar col-
lectors and storage.
Pay attention to the system overall flow resistance (ex-
changer, solar collectors and pipes) at the maximum flow
rate conditions provided.