Sensor connections
- Route probe cables through the cable guides (F), the
fairleads (Ps), the passages on the insulation (Is), the
solar station outlets (Us/Ua) and connect them to ter-
minal board M4 of solar regulator (terminals S1-S2-
S3-S4) making reference to the instructions provided
in the specific regulator manual.
Upon connection, or should it be necessary to increase
probe cable length, refer to these remarks:
- Absolutely avoid laying probe cable together with
mains power cables and/or AC cables
- Absolutely avoid routing cables close to strong mag-
netic fields
- Avoid any cable jointing as much as possible; solder
and duly insulate any indispensable jointing
- Use twisted and shielded wires
- Use cables having a cross-section of over 0.5 mm
2
Solar controller power connections
- Route the supply cable through the cable guides (F),
the fairleads (Pa), the passages on the insulation (Ia),
the solar station outlets (Ua) and connect it to termi-
nal board M1 of solar regulator (terminals L-N-GND)
making reference to the instructions provided in the
specific regulator manual.
Once electrical connections are completed, fasten cables
using the guides supplied, close regulator cover and solar
station protection housing.