5   CONTROL PANEL 

A and B

DHW setpoint adjustment

Parameter selection

C and D

Heating setpoint adjustment

Parameter setting

A+B

DHW Comfort menu (on the main page and with a status other than OFF)

B

Return to previous screen/cancel choice

Press >2 sec to return to main page

1

Change operating status (OFF, SUMMER and WINTER)

2

Reset alarm (RESET)

Interrupt venting cycle 

3

Access to INFO menu 

Access to parameter setting menu

Access to password entry page

ENTER function

1+3

Key lock/unlock

2+3

When the boiler is OFF, activates combustion analysis (CO)

°C

5

0

8

.

A

A

C

C

BB

D

D

 1          2        3

 1          2        3

Connection to a WIFI device
Fault or deadline timer call for service

In the event of a fault together with the 

icon (apart from 

flame and water alarms

Indicates presence of flame. In the event of a flame failure, the 

icon is 

Flashes with temporary water alarms, fixed with permanent alarm

Present if heating mode is active; flashes with heating request 

in progress
Present if DHW mode is active; flashes with DHW request in 

progress

°C

Unit of measurement for temperature

rpm

Number of fan rotations

bar

Pressure value

6   USER INSTRUCTIONS 

 

ƒ

Position the system’s main switch to the “on” position.

 

ƒ

Open the gas tap to allow the fuel to flow.

 

ƒ

When the power is enabled, all the icons and segments will light up 

for 1 sec and the firmware revision will be visualised for 3 sec: 

psi

bar

rpm

°F

°C

1

88

8

.

 

ƒ

The automatic venting cycle will then be launched (if it is enabled) and 

will last 4 min (for the details, refer to the paragraph “3.3 Venting cycle”

).

 

ƒ

The interface will show the status active in that moment.

 

b

Adjust the ambient thermostat to the required temperature (~ 

20°C)  or,  if  the  system  is  equipped  with  a  timed  thermostat  or 

programmer, make sure it is “active” and adjusted

 (~20°C).

 

ƒ

Bring the boiler to WINTER or SUMMER mode. 

6.1  Operating status 

 

ƒ

Pressing key 1, the operating type switches cyclically between OFF - 

SUMMER - WINTER and then OFF again.

In standby, the display shows the system pressure, in case of a heating 

request it shows the flow temperature, while in case of a domestic hot 

water request the domestic hot water temperature.

°C

50

4

°C

50

8

---

.

1

5

bar

.

CH delivery 

temperature

DHW temperature

stand-by

The delivery temperature is shown on the display. If there is a DHW 

request, the DHW temperature will be shown

.

WINTER MODE

   

The boiler activates the heating and DHW function. The presence of the 

“ ” icon indicates a heat request and burner switch-on.

SUMMER MODE 

The boiler activates the traditional DHW function. 

WINTER

SUMMER

°C

50

8

°C

50

4

Each time the keys are pressed, the boiler makes 

a sound signal (Buzzer); it is possible through 

parameter 006 Buzzer to manage the enabling 

(1) or disabling (0) of the sound.

Note: values in thousands are displayed/100, for example 

6500 rpm = 65.0

PARAMETER 

NAME

DESCRIPTION

I001

Screed heater hours

Number of hours of screed heater function activation 

I002

Delivery probe

Boiler delivery probe value 

I003

Return probe

Boiler return probe value 

I004

DHW probe

DHW probe value with boiler in instantaneous mode 

I005

OT+ DHW setpoint

DHW setpoint sent by OT+ remote control to the boiler

I008

Flue gas probe

Flue gas probe value

I009

External probe

Instantaneous external probe value

I010

External temperature for thermoregulation

Filtered external probe value used in the temperature control algorithm to calculate 

the heating setpoint 

I011

DHW fl ow rate

DHW setpoint (only with OT+ connection)

I012

Fan rotations

Number of fan rotations (rpm) 

I013

Flow sensor (main zone)

Value of the main zone fl ow sensor (when P4.12 = 1) 

I015

Flue gas probe counter

Number of operating hours of the heat exchanger in “condensing mode” 

I016

Delivery setpoint (main zone)

Delivery setpoint for the main zone

I017

OT+ CH setpoint

Heating setpoint sent by the OT+ timed thermostat to the boiler

I018

System pressure

System pressure level 

I032

DHW comfort

DHW comfort mode 

I033

Special DHW functions

Special functions active for high DHW inlet temperatures

I034

ID board

Identifi cation of the electronic board

I035

FW board revision

Firmware revision of the electronic board

I038

WIFI pendrive radio signal

Indicates the quality of the WIFI connection

I039

ALARM LOG 1  (the oldest)

List of the last fi ve alarms recorded

I040

ALARM LOG 2

I041

ALARM LOG 3

I042

ALARM LOG 4

I043

ALARM LOG 5 (the latest)

Содержание 20183151

Страница 1: ...C 5 0 8 Ciao EN INSTALLER AND USER MANUAL RO MANUAL DE INSTALARE I UTILIZARE...

Страница 2: ...at requirements of the system and in fact it is possible to set the range rated parameter as shown in the specific paragraph After setting the desired output report the value in the table on the back...

Страница 3: ...to harm hu man health and without employing procedures or methods which may damage the environment At the end of its life the product should be not be di sposed of as solid urban waste but rather it...

Страница 4: ...Hz 230 50 230 50 Protection level IP X5D X5D Stop loss W 30 32 Losses at the flue with burner off burner on 0 09 2 80 0 08 2 26 Heating operation Maximum pressure bar 3 3 Minimum pressure for standard...

Страница 5: ...Countries contained in the data plate regardless of the present translation language NOTE with reference to the Delegated Regulation EU No 811 2013 the information in the table can be used for comple...

Страница 6: ...ipe and pick up of combustion air from outside It does not require an air intake point in the installation area The appliance can be installed indoors fig A or outdoors but in a partially protected pl...

Страница 7: ...Ifremovingthesidepanels putthembackintheirinitialposition referring to the adhesive label on its wall b If the front panel is damaged it must be replaced b The noise absorbing panels inside the front...

Страница 8: ...length that can be installed ONLY with class H1 discharge pipes The 50 or 60 or 80 configurations contain Lab test data In the event of installations that differ from the indications in the standard...

Страница 9: ...REQUEST FROM OT CHRONOTHERMOSTAT In this case the delivery setpoint is calculated by chronohermostat on the basis of the external temperature value and the difference between the real ambient temperat...

Страница 10: ...Combustion control sequence 1 4 5 2 3 Installer manual QR fumes adaptor 90 80 70 60 50 40 30 20 10 Temperatura di mandata C Temperatura esterna C 20 15 10 5 0 5 10 15 20 RIDUZIONE NOTTURNA PARALLELA C...

Страница 11: ...minimum fan speed 307 maximum fan speed 308 slow ignition 309 maximum fan speed for heating table 3 MAX NO FAN ROTATIONS METHANE GAS G20 LPG G31 25C f CH DHW 7 000 8 700 6 900 8 500 rpm 30C f CH DHW 7...

Страница 12: ...s 2 sec Res If the correct operating conditions have been restored the boiler will start up again automatically In the presence of a remote control a maximum of 5 consecutive unlocking attempts are av...

Страница 13: ...the heat exchanger with a soft bristled brush DO NOT USE METAL BRUSHES THAT COULD DAMAGE THE COM PONENTS Clean the spaces between the coils using a 0 4 mm thick blade also available in a kit Vacuum a...

Страница 14: ...P MAIN ZONE HT 80 5 LT 45 0 INSTALLER HT 80 5 LT 45 0 417 MIN TEMP MAIN ZONE 20 MAXTEMP MAINZONE INSTALLER HT 40 LT 20 418 THERMOREGULATION MAIN ZONE 0 1 INSTALLER ifext probepresent 0 419 CURVE SLOPE...

Страница 15: ...point value that can be set range 20 C 80 5 C default 80 5 C for high temperature systems range 20 C 45 C default 45 C for low temperature systems NB the value of 416 cannot be lower than 417 417 This...

Страница 16: ...r make sure it is active and adjusted 20 C Bring the boiler to WINTER or SUMMER mode 6 1 Operating status Pressing key 1 the operating type switches cyclically between OFF SUMMER WINTER and then OFF a...

Страница 17: ...output then maintained until the delivery water temperature reaches 35 C the display shows AF1 DHW anti freeze this function is activated if the temperature meas ured by the domestic hot water probe d...

Страница 18: ...clusiv unor persoane calificate profesional a Produc torul nu i asum r spunderea pentru eventualele daune cauzate de nerespectarea indica iilor de mai sus i sau a normelor n vigoare n anumite sec iuni...

Страница 19: ...colectare corespunz toare b De eurile trebuie s fie eliminate f r riscuri pentru s n tatea uman i f r a recurge la proceduri sau la metode care ar putea cauza daune de mediu La sf r itul ciclului de...

Страница 20: ...X5D Pierderi la oprire W 30 32 Pierderi la co cu arz torul stins arz torul aprins 0 09 2 80 0 08 2 26 Func ionare pentru circuitul de nc lzire Presiune maxim bari 3 3 Presiune minim pentru func ionar...

Страница 21: ...punere n func iune NOT conform regulamentului delegat UE nr 811 2013 datele reprezentate n tabel pot fi utilizate pentru completarea fi ei produsului i etichetare n cazul produ selor pentru nc lzirea...

Страница 22: ...er n spa iul de instalare 2 central de tip C13 C13x C33 C33x C43 C43x C53 C53x C63 C63x C83 C83x C93 C93x aparat cu carcas etan cu conduct de evacuare a gazelor arse i aspirare a aerului de ardere din...

Страница 23: ...omponentele interne ndep rta i carcasa dup cum se indic n figur b Dac scoate i panourile laterale pune i le napoi n pozi ia ini ial referindu v la eticheta adeziv de pe peretele s u b Eventuala deteri...

Страница 24: ...51 255 431 7 600 9 300 24 57 285 465 7 700 9 400 27 63 315 500 modelul B 7 400 8 700 0 7 35 190 7 500 8 800 4 17 85 256 7 600 8 900 7 23 115 300 7 700 9 000 10 29 145 340 7 800 9 100 13 35 175 380 7 9...

Страница 25: ...IT 3 4 Setarea termoregl rii Reglarea termic func ioneaz numai cu sonda extern conectat i este activ numai pentru func ia NC LZIRE Pentru activarea TERMOREGL RII proceda i n felul urm tor seta i param...

Страница 26: ...loare de referin de alimentare n ap de 20 C ulterior cresc nd conform tabelului de mai jos ZI OR TEMPERATUR 1 0 20 C 6 22 C 12 24 C 18 26 C 2 0 28 C 12 30 C 3 0 32 C 4 0 35 C 5 0 35 C 6 0 30 C 7 0 25...

Страница 27: ...tur de 95 C arz torul se opre te Reaprinde rea va avea loc atunci c nd aceast temperatur va cobor sub 75 C b Func ia de analiz a arderii este efectuat n mod normal cu vana cu trei c i setat pe nc lzi...

Страница 28: ...unc ionarea n modul de nc lzire alimenta i centrala seta i parametrul 310 Gama nominal Range rated Seta i valoarea maxim de nc lzire rot min i confirma i 0 0 7 rpm 0 0 7 rpm confirmare rpm MAX nregist...

Страница 29: ...bar presiune ridicat veri ca i instala ia semnalizare 4 NTRE INERE I CUR ARE ntre inerea periodic este o obliga ie prev zut de normele n vigoare i este esen ial pentru siguran a randamentul i durata...

Страница 30: ...t continua i cu procedurile de cur are a arz torului Cur a i arz torul cu o perie cu peri moi av nd grij s nu deteriora i panoul izolator i electrodul NU UTILIZA I PERII METALICE CARE POT DETERIORA CO...

Страница 31: ...zactiva avertizarea sonor 0 avertizor sonor buzzer OPRIT 1 avertizor sonor buzzer PORNIT 301 Pentru a seta tipul de con gura ie hidraulic a centralei 0 DOAR NC LZIRE 1 ACM INSTANTANEE FLUXOSTAT 2 ACM...

Страница 32: ...ntru a seta valoarea de referin maxim ce se poate seta pentru nc lzire interval 20 C 80 5 C implicit 80 5 C pentru instala ii cu temperatur ridicat interval 20 C 45 C implicit 45 C pentru instala ii c...

Страница 33: ...3 Ciclul de evacuare a aerului Ulterior interfa a trece la afi area st rii active n acel moment b Regla i termostatul de mediu la temperatura dorit 20 C sau dac instala ia este dotat cu un cronotermos...

Страница 34: ...men inut p n c nd temperatura apei de alimentare ajunge la 55 C pe ecran se afi eaz AF2 antiblocare circulator Pompa de circula ie se activeaz la fiecare 24 de ore timp de 30 de secunde 6 7 Oprirea p...

Страница 35: ...ei c i 4 Traductor presiune 5 By pass automat 6 Sond ap cald menajer 7 Sond tur 8 Termostat limit 9 Schimb tor principal 10 Sond retur 11 Supap inferioar de aerisire 12 Vas de expansiune 13 Pomp de ci...

Страница 36: ...a este deja dotat cu o pomp de circula ie cu conexiuni hidraulice i electrice a c rei performan util disponibil este indicat pe grafic Func ia anti blocare este activ numai c nd centrala termic este a...

Страница 37: ...r on primary circuit S M Temperature flow sensor on primary circuit S F Flue gas sensor T L A Water limit thermostat T P Pressure transducer S S Domestic hot water circuit temperature return sensor F...

Страница 38: ...85 vertical vertical 90 bend 80 125 80 125 14 12 1 1 5 130 curba 90 80 125 adaptor from 60 100 to 80 125 adaptor de la 60 100 la 80 125 adaptor vertical connection 80 100 adaptor vertical conexiune 8...

Страница 39: ...tabelul pentru ac iuni mai imediate bar rpm C 1 88 8 sau or sau or Actions Sequence password entry points 1 7 parameter choice points 8 10 modify and confirm parameter points 11 12a exit without savin...

Страница 40: ...813 2013 Reglementare delegat UE nr 814 2013 CIAO boiler complies with basic requirements of the following Di rectives Regulation UE 2016 426 Efficiency directive Article 7 2 and Annex III of directi...

Отзывы: