5 CONTROL PANEL
A and B
DHW setpoint adjustment
Parameter selection
C and D
Heating setpoint adjustment
Parameter setting
A+B
DHW Comfort menu (on the main page and with a status other than OFF)
B
Return to previous screen/cancel choice
Press >2 sec to return to main page
1
Change operating status (OFF, SUMMER and WINTER)
2
Reset alarm (RESET)
Interrupt venting cycle
3
Access to INFO menu
Access to parameter setting menu
Access to password entry page
ENTER function
1+3
Key lock/unlock
2+3
When the boiler is OFF, activates combustion analysis (CO)
°C
5
0
8
.
A
A
C
C
BB
D
D
1 2 3
1 2 3
Connection to a WIFI device
Fault or deadline timer call for service
In the event of a fault together with the
icon (apart from
flame and water alarms
Indicates presence of flame. In the event of a flame failure, the
icon is
Flashes with temporary water alarms, fixed with permanent alarm
Present if heating mode is active; flashes with heating request
in progress
Present if DHW mode is active; flashes with DHW request in
progress
°C
Unit of measurement for temperature
rpm
Number of fan rotations
bar
Pressure value
6 USER INSTRUCTIONS
Position the system’s main switch to the “on” position.
Open the gas tap to allow the fuel to flow.
When the power is enabled, all the icons and segments will light up
for 1 sec and the firmware revision will be visualised for 3 sec:
psi
bar
rpm
°F
°C
1
88
8
.
The automatic venting cycle will then be launched (if it is enabled) and
will last 4 min (for the details, refer to the paragraph “3.3 Venting cycle”
).
The interface will show the status active in that moment.
b
Adjust the ambient thermostat to the required temperature (~
20°C) or, if the system is equipped with a timed thermostat or
programmer, make sure it is “active” and adjusted
(~20°C).
Bring the boiler to WINTER or SUMMER mode.
6.1 Operating status
Pressing key 1, the operating type switches cyclically between OFF -
SUMMER - WINTER and then OFF again.
In standby, the display shows the system pressure, in case of a heating
request it shows the flow temperature, while in case of a domestic hot
water request the domestic hot water temperature.
°C
50
4
°C
50
8
---
.
1
5
bar
.
CH delivery
temperature
DHW temperature
stand-by
The delivery temperature is shown on the display. If there is a DHW
request, the DHW temperature will be shown
.
WINTER MODE
The boiler activates the heating and DHW function. The presence of the
“ ” icon indicates a heat request and burner switch-on.
SUMMER MODE
The boiler activates the traditional DHW function.
WINTER
SUMMER
°C
50
8
°C
50
4
Each time the keys are pressed, the boiler makes
a sound signal (Buzzer); it is possible through
parameter 006 Buzzer to manage the enabling
(1) or disabling (0) of the sound.
Note: values in thousands are displayed/100, for example
6500 rpm = 65.0
PARAMETER
NAME
DESCRIPTION
I001
Screed heater hours
Number of hours of screed heater function activation
I002
Delivery probe
Boiler delivery probe value
I003
Return probe
Boiler return probe value
I004
DHW probe
DHW probe value with boiler in instantaneous mode
I005
OT+ DHW setpoint
DHW setpoint sent by OT+ remote control to the boiler
I008
Flue gas probe
Flue gas probe value
I009
External probe
Instantaneous external probe value
I010
External temperature for thermoregulation
Filtered external probe value used in the temperature control algorithm to calculate
the heating setpoint
I011
DHW fl ow rate
DHW setpoint (only with OT+ connection)
I012
Fan rotations
Number of fan rotations (rpm)
I013
Flow sensor (main zone)
Value of the main zone fl ow sensor (when P4.12 = 1)
I015
Flue gas probe counter
Number of operating hours of the heat exchanger in “condensing mode”
I016
Delivery setpoint (main zone)
Delivery setpoint for the main zone
I017
OT+ CH setpoint
Heating setpoint sent by the OT+ timed thermostat to the boiler
I018
System pressure
System pressure level
I032
DHW comfort
DHW comfort mode
I033
Special DHW functions
Special functions active for high DHW inlet temperatures
I034
ID board
Identifi cation of the electronic board
I035
FW board revision
Firmware revision of the electronic board
I038
WIFI pendrive radio signal
Indicates the quality of the WIFI connection
I039
ALARM LOG 1 (the oldest)
List of the last fi ve alarms recorded
I040
ALARM LOG 2
I041
ALARM LOG 3
I042
ALARM LOG 4
I043
ALARM LOG 5 (the latest)