> 2 sec

MAX

MIN

+

Co

---

0

0

6

.

rpm

0

0

6

.

rpm

or

fan speed 

in CH

The displayed value refers to the number of revolutions divided by 100.

 

ƒ

Set the maximum rpm value.

0

0

7

.

rpm

0

0

7

.

rpm

confirm

MAX

rpm

The boiler works at the maximum power level.

 

ƒ

Check the analyser to ensure the max CO

2

 value complies with the indica-

tion given in the table. If the value is different, calibrate the gas valve - see 

paragraph “3.10 Gas valve calibration”

.

table 1

CO

2

 max

METHANE 

GAS (G20)

LPG 

(G31)

25C f

9,0

10,0

%

30C f

9,0

10,0

%

 

ƒ

Set the minimum rpm value

0

1

6

.

rpm

0

1

6

.

rpm

confirm

MIN

rpm

The boiler works at the minimum power level.

 

ƒ

Check the analyser to ensure the min CO

2

 value complies with the indica-

tion given in the table. If the value is different, calibrate the gas valve - see 

paragraph 

“3.10 Gas valve calibration”.

table 2

CO

2

 min

METHANE 

GAS (G20)

LPG 

(G31)

25C f

9,0

10,0

%

30C f

9,0

10,0

%

After completing the check:

 

ƒ

quit the function by pressing

0

5

6

.

rpm

exit function

 

ƒ

reposition the previously removed components

 

ƒ

set the boiler to the required operating mode, depending on the season

 

ƒ

regulate the heat request temperature values according to the customer’s 

needs.

 

b

When the combustion analysis function is active, all heat requests are 

inhibited and the message “CO” appears on the display.

IMPORTANT

The combustion analysis function is active for max. 15 minutes; the burner 

shuts down if a delivery temperature of 95°C is reached. It will ignite again when 

the temperature falls below 75°C.

 

b

The combustion analysis function is usually carried out with the 3-way 

valve on heating. The 3-way valve can be switched to DHW by genera-

ting a DHW request at the maximum output while the function itself is still 

active. In this case, the DHW temperature will be limited to a maximum 

value of 65°C. Wait for the burner to fire.

3.9  Adjustments

The boiler has already been adjusted by the manufacturer. If the adjustments 

need to be made again however e.g. following extraordinary maintenance, after 

the replacement of the gas valve

after conversion from methane gas to LPG 

or vice versa

, or after a new regulation for inside-chimney pipes, 

follow the 

procedures described below.

The adjustment of the maximum and minimum output, maximum heating and slow 

ignition must be made in the sequence indicated, and by qualified personnel only

:

 

ƒ

power up the boiler

 

ƒ

set the parameters

306

minimum fan speed

307

maximum fan speed

308

slow ignition

309

maximum fan speed for heating

table 3

MAX. NO. FAN 

ROTATIONS 

METHANE GAS 

(G20)

LPG

 (G31)

25C f  CH - DHW

7.000-8.700

6.900-8.500

rpm

30C f  CH - DHW

7.400-8.700

7.400-8.700

rpm

table 4

MIN. NO. FAN 

ROTATIONS 

METHANE GAS 

(G20)

LPG

 (G31)

25C f 

1.500

2.050

rpm

30C f

1.500

1.700

rpm

table 5

NO. FAN ROTATIONS 

SLOW IGNITION

METHANE GAS 

(G20)

LPG

 (G31)

25C f - 30C f 

5.500

5.500

rpm

3.10  Gas valve calibration

Run the CO

2

 check procedure as explained in paragraph “3.8 Combustion 

analysis”. If the values need to be modified, proceed as follows

:

 

ƒ

check the CO

2

 adjustment values with the casing closed

 

ƒ

remove the casing as explained in paragraph “2.5 Removing the casing”

 

ƒ

check the CO

2

 adjustment values again, with the casing open

 

ƒ

on the basis of the difference in values with the casing closed and open, if 

necessary bring the CO

2

 to the value shown in the table (1 and 2) - (minus) 

the difference found. Example:

 

ƒ

CO

2

 value measured with the casing closed

 = 8,5%

 

ƒ

CO

2

 value measured with the casing open

 = 8,3%

 

ƒ

value to be set for CO

2

 with the casing open

 = 8,8%

 

ƒ

value to be set for CO

2

 with the casing closed

 = 9,0%

 

ƒ

to adjust the CO

2

 value:

 

ƒ

rotate the max. power adjustment screw clockwise to reduce the value

or anti-clockwise to increase it

 

ƒ

rotate the min. power adjustment screw clockwise to increase the value

or anti-clockwise to reduce it

 

ƒ

with the casing open and after adjusting the CO

2

 value at the minimum 

power, check the adjustment of the 

CO

2

 at the maximum power again

 

ƒ

after completing the adjustments, replace the casing and check the 

CO

2

 

corresponds to the value shown in the table 1 and 2.

CO

2

 -

CO

2

 +

Maximum output 

adjustment screw

Maximum output 

adjustment screw

3.11  Gas conversion

Conversion from the gas of one family to the gas of another family can be 

done easily even when the boiler is already installed.

This operation must be carried out by professionally qualified personnel. The 

boiler is designed to operate with methane gas (G20) or LPG (G31) according 

to the product label. The boiler can be transformed to LPG or to methane gas 

(G20) by means of special kits.

For disassembly refer to instructions below:

 

ƒ

disconnect the boiler from the electricity supply and turn off the gas tap

 

ƒ

remove the casing as explained in paragraph “2.5 Removing the casing”

 

ƒ

release the instrument panel and rotate it forwards

 

ƒ

unscrew the ramp nut from the gas valve and rotate the ramp so as to have 

access to the gas nozzle (

B

) in the outlet fitting

 

ƒ

remove the nozzle (

B

) and replace it with the one from the kit

Содержание 20183151

Страница 1: ...C 5 0 8 Ciao EN INSTALLER AND USER MANUAL RO MANUAL DE INSTALARE I UTILIZARE...

Страница 2: ...at requirements of the system and in fact it is possible to set the range rated parameter as shown in the specific paragraph After setting the desired output report the value in the table on the back...

Страница 3: ...to harm hu man health and without employing procedures or methods which may damage the environment At the end of its life the product should be not be di sposed of as solid urban waste but rather it...

Страница 4: ...Hz 230 50 230 50 Protection level IP X5D X5D Stop loss W 30 32 Losses at the flue with burner off burner on 0 09 2 80 0 08 2 26 Heating operation Maximum pressure bar 3 3 Minimum pressure for standard...

Страница 5: ...Countries contained in the data plate regardless of the present translation language NOTE with reference to the Delegated Regulation EU No 811 2013 the information in the table can be used for comple...

Страница 6: ...ipe and pick up of combustion air from outside It does not require an air intake point in the installation area The appliance can be installed indoors fig A or outdoors but in a partially protected pl...

Страница 7: ...Ifremovingthesidepanels putthembackintheirinitialposition referring to the adhesive label on its wall b If the front panel is damaged it must be replaced b The noise absorbing panels inside the front...

Страница 8: ...length that can be installed ONLY with class H1 discharge pipes The 50 or 60 or 80 configurations contain Lab test data In the event of installations that differ from the indications in the standard...

Страница 9: ...REQUEST FROM OT CHRONOTHERMOSTAT In this case the delivery setpoint is calculated by chronohermostat on the basis of the external temperature value and the difference between the real ambient temperat...

Страница 10: ...Combustion control sequence 1 4 5 2 3 Installer manual QR fumes adaptor 90 80 70 60 50 40 30 20 10 Temperatura di mandata C Temperatura esterna C 20 15 10 5 0 5 10 15 20 RIDUZIONE NOTTURNA PARALLELA C...

Страница 11: ...minimum fan speed 307 maximum fan speed 308 slow ignition 309 maximum fan speed for heating table 3 MAX NO FAN ROTATIONS METHANE GAS G20 LPG G31 25C f CH DHW 7 000 8 700 6 900 8 500 rpm 30C f CH DHW 7...

Страница 12: ...s 2 sec Res If the correct operating conditions have been restored the boiler will start up again automatically In the presence of a remote control a maximum of 5 consecutive unlocking attempts are av...

Страница 13: ...the heat exchanger with a soft bristled brush DO NOT USE METAL BRUSHES THAT COULD DAMAGE THE COM PONENTS Clean the spaces between the coils using a 0 4 mm thick blade also available in a kit Vacuum a...

Страница 14: ...P MAIN ZONE HT 80 5 LT 45 0 INSTALLER HT 80 5 LT 45 0 417 MIN TEMP MAIN ZONE 20 MAXTEMP MAINZONE INSTALLER HT 40 LT 20 418 THERMOREGULATION MAIN ZONE 0 1 INSTALLER ifext probepresent 0 419 CURVE SLOPE...

Страница 15: ...point value that can be set range 20 C 80 5 C default 80 5 C for high temperature systems range 20 C 45 C default 45 C for low temperature systems NB the value of 416 cannot be lower than 417 417 This...

Страница 16: ...r make sure it is active and adjusted 20 C Bring the boiler to WINTER or SUMMER mode 6 1 Operating status Pressing key 1 the operating type switches cyclically between OFF SUMMER WINTER and then OFF a...

Страница 17: ...output then maintained until the delivery water temperature reaches 35 C the display shows AF1 DHW anti freeze this function is activated if the temperature meas ured by the domestic hot water probe d...

Страница 18: ...clusiv unor persoane calificate profesional a Produc torul nu i asum r spunderea pentru eventualele daune cauzate de nerespectarea indica iilor de mai sus i sau a normelor n vigoare n anumite sec iuni...

Страница 19: ...colectare corespunz toare b De eurile trebuie s fie eliminate f r riscuri pentru s n tatea uman i f r a recurge la proceduri sau la metode care ar putea cauza daune de mediu La sf r itul ciclului de...

Страница 20: ...X5D Pierderi la oprire W 30 32 Pierderi la co cu arz torul stins arz torul aprins 0 09 2 80 0 08 2 26 Func ionare pentru circuitul de nc lzire Presiune maxim bari 3 3 Presiune minim pentru func ionar...

Страница 21: ...punere n func iune NOT conform regulamentului delegat UE nr 811 2013 datele reprezentate n tabel pot fi utilizate pentru completarea fi ei produsului i etichetare n cazul produ selor pentru nc lzirea...

Страница 22: ...er n spa iul de instalare 2 central de tip C13 C13x C33 C33x C43 C43x C53 C53x C63 C63x C83 C83x C93 C93x aparat cu carcas etan cu conduct de evacuare a gazelor arse i aspirare a aerului de ardere din...

Страница 23: ...omponentele interne ndep rta i carcasa dup cum se indic n figur b Dac scoate i panourile laterale pune i le napoi n pozi ia ini ial referindu v la eticheta adeziv de pe peretele s u b Eventuala deteri...

Страница 24: ...51 255 431 7 600 9 300 24 57 285 465 7 700 9 400 27 63 315 500 modelul B 7 400 8 700 0 7 35 190 7 500 8 800 4 17 85 256 7 600 8 900 7 23 115 300 7 700 9 000 10 29 145 340 7 800 9 100 13 35 175 380 7 9...

Страница 25: ...IT 3 4 Setarea termoregl rii Reglarea termic func ioneaz numai cu sonda extern conectat i este activ numai pentru func ia NC LZIRE Pentru activarea TERMOREGL RII proceda i n felul urm tor seta i param...

Страница 26: ...loare de referin de alimentare n ap de 20 C ulterior cresc nd conform tabelului de mai jos ZI OR TEMPERATUR 1 0 20 C 6 22 C 12 24 C 18 26 C 2 0 28 C 12 30 C 3 0 32 C 4 0 35 C 5 0 35 C 6 0 30 C 7 0 25...

Страница 27: ...tur de 95 C arz torul se opre te Reaprinde rea va avea loc atunci c nd aceast temperatur va cobor sub 75 C b Func ia de analiz a arderii este efectuat n mod normal cu vana cu trei c i setat pe nc lzi...

Страница 28: ...unc ionarea n modul de nc lzire alimenta i centrala seta i parametrul 310 Gama nominal Range rated Seta i valoarea maxim de nc lzire rot min i confirma i 0 0 7 rpm 0 0 7 rpm confirmare rpm MAX nregist...

Страница 29: ...bar presiune ridicat veri ca i instala ia semnalizare 4 NTRE INERE I CUR ARE ntre inerea periodic este o obliga ie prev zut de normele n vigoare i este esen ial pentru siguran a randamentul i durata...

Страница 30: ...t continua i cu procedurile de cur are a arz torului Cur a i arz torul cu o perie cu peri moi av nd grij s nu deteriora i panoul izolator i electrodul NU UTILIZA I PERII METALICE CARE POT DETERIORA CO...

Страница 31: ...zactiva avertizarea sonor 0 avertizor sonor buzzer OPRIT 1 avertizor sonor buzzer PORNIT 301 Pentru a seta tipul de con gura ie hidraulic a centralei 0 DOAR NC LZIRE 1 ACM INSTANTANEE FLUXOSTAT 2 ACM...

Страница 32: ...ntru a seta valoarea de referin maxim ce se poate seta pentru nc lzire interval 20 C 80 5 C implicit 80 5 C pentru instala ii cu temperatur ridicat interval 20 C 45 C implicit 45 C pentru instala ii c...

Страница 33: ...3 Ciclul de evacuare a aerului Ulterior interfa a trece la afi area st rii active n acel moment b Regla i termostatul de mediu la temperatura dorit 20 C sau dac instala ia este dotat cu un cronotermos...

Страница 34: ...men inut p n c nd temperatura apei de alimentare ajunge la 55 C pe ecran se afi eaz AF2 antiblocare circulator Pompa de circula ie se activeaz la fiecare 24 de ore timp de 30 de secunde 6 7 Oprirea p...

Страница 35: ...ei c i 4 Traductor presiune 5 By pass automat 6 Sond ap cald menajer 7 Sond tur 8 Termostat limit 9 Schimb tor principal 10 Sond retur 11 Supap inferioar de aerisire 12 Vas de expansiune 13 Pomp de ci...

Страница 36: ...a este deja dotat cu o pomp de circula ie cu conexiuni hidraulice i electrice a c rei performan util disponibil este indicat pe grafic Func ia anti blocare este activ numai c nd centrala termic este a...

Страница 37: ...r on primary circuit S M Temperature flow sensor on primary circuit S F Flue gas sensor T L A Water limit thermostat T P Pressure transducer S S Domestic hot water circuit temperature return sensor F...

Страница 38: ...85 vertical vertical 90 bend 80 125 80 125 14 12 1 1 5 130 curba 90 80 125 adaptor from 60 100 to 80 125 adaptor de la 60 100 la 80 125 adaptor vertical connection 80 100 adaptor vertical conexiune 8...

Страница 39: ...tabelul pentru ac iuni mai imediate bar rpm C 1 88 8 sau or sau or Actions Sequence password entry points 1 7 parameter choice points 8 10 modify and confirm parameter points 11 12a exit without savin...

Страница 40: ...813 2013 Reglementare delegat UE nr 814 2013 CIAO boiler complies with basic requirements of the following Di rectives Regulation UE 2016 426 Efficiency directive Article 7 2 and Annex III of directi...

Отзывы: