1  GENERAL INFORMATION

1 .1  General precautions

 

b

After removing the packing, check the integrity and 

completeness of the contents. If they do not corre-

spond, contact the 

B

 agency that sold the unit.

 

b

This product must be installed by a legally qualified 

heating engineer. On completion of the installation, 

the installer must issue the owner with a declara-

tion of conformity confirming that the installation has 

been completed to the highest standards in com-

pliance with the instructions provided by 

B

 in this 

instruction manual, and that it conforms to all appli-

cable laws and standards.

 

b

The installation area must be dry. Respect the mini-

mum distances for maintenance and installation. 

 

b

The 

B

 

IDRA HP

 boiler must be destined for the use 

for which it was expressly manufactured by 

B

.  

B

 accepts no responsibility, either contractual or 

extra contractual, for damage to persons, animals or 

property arising from incorrect installation or adjust-

ment, maintenance or improper use.

 

b

Should water leak from the unit, disconnect the boiler 

from the mains electrical supply and close the water 

supply, and urgently call the 

B

 Technical Service 

Centre or professionally qualified personnel.

 

b

Maintenance on the boiler must be performed at least 

once per year.

 

b

If the boiler is not used for a long period, proceed as 

follows:

 -Set the master switch on the system to OFF

 -Empty the solar circuit (if present) and the thermal 

system

 -Close the water system interception devices.

 

b

If the boiler is part of a solar system, mix anti-free-

ze (glycol propylene), available separately, with wa-

ter in a variable percentage (30÷50%), following the 

instructions described in the 

B

 setting up and 

maintenance manual.

 

b

Always fill the solar system (if present) with the glycol/

water mix in the percentage indicated in the 

B

 

setting up and maintenance manual.

 

b

This instructions booklet is an integral part of the unit 

and consequently must be kept with care and must 

ALWAYS accompany the unit, even when this is tran-

sferred to another owner or user or transferred onto 

another system. If it gets damaged or lost, request 

another copy from the local 

B

 Technical Service 

Centre.

1 .2  Fundamental safety rules

The use of products that use of electricity and water re-

quires the observation of some fundamental safety rules 

such as:

 

a

The use of the unit by unassisted disabled persons or 

children is forbidden.

 

a

It is forbidden to touch the boiler if barefoot and with 

parts of the body that are wet or humid.

 

a

It is forbidden to clean or perform any technical in-

tervention before disconnecting the boiler from the 

mains power supply, setting the master switch on the 

system and that on the boiler control panel to “OFF”.

 

a

It is forbidden to modify the safety or adjustment units 

without authorisation and the indications of the boiler 

manufacturer.

 

a

It is forbidden to pull out or twist the electric cables 

coming out of the boiler, even when disconnected 

from the mains power supply.

 

a

It is forbidden to expose the boiler to atmospheric 

agents because it is not designed for outdoor ope-

ration.

 

a

It is forbidden to abandon and leave the packaging 

material within the reach of children as it can be a 

source of risk.

 

a

In the case of a loss of pressure in the solar system 

it is forbidden to top up with just water, as there is a 

risk of freezing.

 

a

It is forbidden to use connection or safety devices 

which are untested or unsuitable for use in solar sy-

stems (expansion tanks, pipelines, insulation).

1 .3  Description of the appliance

B

 

IDRA HP

 storage cylinders are designed for use in 

systems with heat pumps and guarantee excellent heat 

transfer thanks to a special, larger coil.

They are internally vitrified to permit the production of do-

mestic hot water (DHW), and have external insulation in the 

form of 50 mm thick rigid polyurethane.

B

 

IDRA HP

  storage cylinders can be fitted with an ad-

ditional (optional) heat exchanger to integrate a solar col-

lector heating circuit.

They come complete with sensor sockets, a magnesium 

anode and a fitting for the installation of an (optional) 

electrical heating element.

1 .3 .1  Main Hydraulic Diagram (fig. 1)

Содержание 20117745

Страница 1: ...litori Boilers IDRA HP Manuale Installatore Installation Manual Istruzioni per l installatore e per il servizio tecnico di assistenza Instructions for the installer and the technical service centre IT...

Страница 2: ...termico garanzia di anni 5 bollitori ed accumuli in abbinamento a pannelli solari termici garanzia di anni 5 4 3 La sostituzione o la riparazione dell intero Prodotto o di una sua com ponente non est...

Страница 3: ...Questo libretto di istruzione contiene importanti informazio ni e suggerimenti che devono essere osservati per il miglior uso possibile del bollitore IDRA HP Rinnovati ringraziamenti Beretta GARANZIA...

Страница 4: ...tto Cod Rev composto da pagine 1 GENERALIT 5 1 1 Avvertenze generali 5 1 2 Regole fondamentali di sicurezza 5 1 3 Descrizione dell apparecchio 5 1 3 1 Schema idraulico di principio fig 1 5 1 4 Dati te...

Страница 5: ...accompagnare il bollitore anche in caso di sua cessione ad altro proprietario o utente op pure di un trasferimento su un altro impianto In caso di danneggiamento o smarrimento richiederne un al tro es...

Страница 6: ...C 45 C 0 5 0 8 m h Acqua di riscaldamento 80 C 60 C 4 1 6 7 m h Potenza resa 80 C 60 C 96 156 kW Produzione sanitaria 10 C 45 C 2 4 3 8 m h Tipo d isolamento Poliuretano espanso mm 50 privo di CFC PU...

Страница 7: ...entino 1 1 1 4 11 Mandata acqua calda 1 1 4 1 1 4 12 Attacco bancale cieco 1 2 1 2 b b Il bollitore B IDRA HP non equipaggiato di cir colatori di carico che devono essere opportunamen te dimensionati...

Страница 8: ...e del bollitore indispensabile controllare che I rubinetti dell acqua di alimentazione del circuito ac qua calda non sanitaria siano aperti fig 6 Gli eventuali allacciamenti idraulici alla pompa di ca...

Страница 9: ...pare parts when required this will ensure that your ma chine is maintained at maximum levels of efficiency with consequent lower running costs This instruction manual contains important indications an...

Страница 10: ...y the unit even when this is tran sferred to another owner or user or transferred onto another system If it gets damaged or lost request another copy from the local B Technical Service Centre 1 2 Fund...

Страница 11: ...ction 10 C 45 C 0 5 0 8 m h Heating water 80 C 60 C 4 1 6 7 m h Output power 80 C 60 C 96 156 kW DHW production 10 C 45 C 2 4 3 8 m h Type of insulation Expanded polyurethane mm 50 CFC free Foamed har...

Страница 12: ...ater exchan ger inlet 1 1 1 4 11 Domestic hot water inlet 1 1 4 1 1 4 12 Hole for pallet fixing bolt blind 1 2 1 2 b b The B IDRA HP boiler is not fitted with load circu lators that must be appropriat...

Страница 13: ...3 1 Setting up Before performing the functional test and the starting up of the boiler it is essential to check the following That the non sanitary hot water circuit water supply taps are open fig 6...

Страница 14: ...14 Beretta IDRA HP Q2 1...

Страница 15: ...15 a b 4 5 6 1 2 9 8 6 5 12 4 3 7 10 11 H G F E D C B A I L 30 45 N M 2 3...

Страница 16: ...e i prodotti Questo fascicolo pertanto non pu essere considerato contratto nei confronti di terzi Commercial Offices Via Risorgimento 23 A 23900 Lecco www berettaboilers com Beretta reserves the right...

Отзывы: