8  OVERALL DIMENSIONS AND WATER FITTINGS

B

 

IDRA N DS

 storage cylinders can also be connected to previously installed hot water sources provided heat output 

is suitable and care is taken to ensure correct water flow directions.

EAF

R

UAC

RC

RL

M

MC

SB

RE

G

H

I

M

N

D

E

C

B

A

AD1

AD2

TR

Psc1

Psr

F

L

O

Psc2

P

DESCRIPTION

IDRA N DS

1500

2000

2600

UAC 

Domestic hot water outlet

1 1/2” F

Ø

MC 

Outlet from boiler

1"1/4 F

Ø

RC 

Return to boiler

1"1/4 F

Ø

Outlet from solar collector

1"1/4 F

Ø

Return to solar collector

1"1/4 F

Ø

RL 

DHW recirculation

1" F

Ø

EAF (SB) Domestic cold water inlet (storage cylinder drain)

1 1/2” F

1"1/4 F

Ø

Psc1 

Diameter/length of boiler sensor socket

8/200

-

-

mm

Psc2 

Diameter/length of boiler sensor socket

-

8/200

mm

Psr 

Diameter/length of solar controller sensor socket

8/200

mm

RE 

Sleeve for electric heating element (not supplied)

1 1/2” F

Ø

AD1 

Diameter/length of first magnesium anode

32/700

Ø/mm

AD2 

Diameter/length of second magnesium anode

32/400

32/700

Ø/mm

TR 

Temperature gauge

1/2" F

Ø

A

1230

1340

1310

mm

B

-

1487

1455

mm

C

1775

2000

1950

mm

D

280

250

235

mm

E

415

400

430

mm

F

525

662

655

mm

G

1125

1205

1085

mm

H

1225

1315

1255

mm

I

1325

1425

1425

mm

L

1420

-

-

mm

M

1730

1870

1845

mm

N

1890

1990

1950

mm

O

2120

2045

2455

mm

P

1200

1300

1450

mm

We recommend that you install isolating valves in the outlet and return lines.

Check the efficiency of the seals when filling/refilling the storage cylinder.

Содержание 20086803

Страница 1: ...Installation and Operation Manual Solar solar storage cylinder IDRA N DS Installation and Operation Manual EN...

Страница 2: ...2...

Страница 3: ...following symbols are used in this manual b CAUTION Identifies actions that require caution and adequate preparation a STOP Identifies actions that you MUST NOT do This manual Code Rev comprises pages...

Страница 4: ...acement immediately Keep the product purchase documents to be present ed to the B authorised Technical Assistance Centre to request a service call under warranty b Size the solar expansion tank so as...

Страница 5: ...t 20052790K4LH3800001 Model IDRA N DS 1500 Code 20052790 Serial Number K4LH3800001 Beretta Caldaie Via Risorgimento 13 23900 Lecco LC Italy Capacit nom sanitaria 1449 L 1 8 mq 3 4 mq 1200 L h 2200 L h...

Страница 6: ...Sleeve for electric heating element 1 1 2 Coil water capacity 19 4 28 1 28 4 L Coil heat exchange surface area 3 4 4 6 4 6 m2 Power absorbed by coil 88 120 110 kW Domestic hot water production 2200 29...

Страница 7: ...ders are equipped with ded icated sockets for the storage cylinder TEMPERATURE GAUGE or TEMPERATURE SENSOR b The installer is responsible for making all necessary connections to the boiler and solar c...

Страница 8: ...1 2 F 1 1 4 F Psc1 Diameter length of boiler sensor socket 8 200 mm Psc2 Diameter length of boiler sensor socket 8 200 mm Psr Diameter length of solar controller sensor socket 8 200 mm RE Sleeve for e...

Страница 9: ...it safe MODELS IDRA N DS 2000 B IDRA N DS storage cylinders come in two separate packages The first contains the painted cylinder protected by a plastic bag and supported on a wooden pallet The secon...

Страница 10: ...equipment and use suitable safety devices b Make sure that any lifting equipment is of adequate capacity to lift and move the storage cylinder a Do not dispose of packaging material into the envi ron...

Страница 11: ...storage cylinder from the pallet cut the straps secure the lifting cables to the lifting points on the top of the storage cylinder carefully lift the storage cylinder and position it as re quired 11...

Страница 12: ...npack all the material from the second package Wrap the insulation 3 around the storage cylinder carefully lining up the fittings with the holes on the inside of the insulation Secure the insulation i...

Страница 13: ...orage cylinder is to be installed 14 INSTALLATION IN OLDER SYSTEMS AND SYSTEMS REQUIRING MODERNISATION When installing B IDRA N DS storage cylinders in old systems or systems requiring modernisation a...

Страница 14: ...ake sure that all circuits have been bled Make sure that the boiler and solar collectors con nected to the system shut down correctly when their mains power switches are turned OFF Provided the above...

Страница 15: ...e cylinder after cleaning it a Do not use abrasive products petrol or triethylene INTERNAL CLEANING Removing and checking the magnesium anode Remove the cap 1 cover 2 and the anode insula tor disc 1 2...

Страница 16: ...functioning Check the pump The water temperature from the boiler is too low Check the temperature setting There is air in the primary circuit Bleed the circuit SOLAR COLLECTOR CIRCUIT FAULT CAUSE SOLU...

Страница 17: ...the environmental impact and save energy in case of brief absences week ends short trips etc and with external temperatures above 0 C set the heater tem perature control where available to the minimu...

Страница 18: ...END USER 18...

Страница 19: ...END USER 19...

Страница 20: ...23 A 23900 Lecco LC www berettaboilers com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefor...

Отзывы: