background image

This manual, Code Doc-0071222 - Rev. 0 (05/16) comprises 20 pages.

3

Dear Customer,

Thank you for choosing a 

B

 solar storage cylinder. You have purchased a modern, quality product that is designed 

to give dependable and safe service and to provide comfort in the home for many years to come. Arrange for your 

B

 

solar storage cylinder to be serviced regularly by an authorised 

B

 service centre. Their personnel are specially trai-

ned to keep your solar storage cylinder efficient and cheap to run. 

B

 service centres also stock any original spare 

parts that might be required.

This manual contains important instructions and precautions that must be observed to ensure the trouble-free installation 

and efficient functioning of your 

B

 solar storage cylinder.

Please accept our renewed thanks for your purchase,

Beretta

CONFORMITY

B

 storage cylinders conform to DIN 4753-3/UNI and UNI EN 10025 standards.

  

   

This product must only be used for the purpose for which it is designed and made, as specified by 

B

B

 

declines all responsibility, contractual or other, for damage to property or injury to persons or animals caused by 

improper installation, adjustment, maintenance or use.

RANGE

MODEL

CODE

IDRA N DS 1500

20052790

IDRA N DS 2000

20052791

IDRA N DS 2600

20086803

ACCESSORIES

For a complete list of accessories and details of their compatibility, refer to the Catalogue.

CONTENTS

The following symbols are used in this manual:

CAUTION! =

 Identifies actions that require caution 

and adequate preparation.

STOP! =

 Identifies actions that you MUST NOT do.

This manual, Code

- Rev.

comprises

pages.

GENERAL                                                                      4

General Safety Information . . . . . . . . . . . . . . . . . .  4

2 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4

Description of the appliance. . . . . . . . . . . . . . . . .  5

4 Identification  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5

System layout  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5

Technical specifications  . . . . . . . . . . . . . . . . . . . .  6

Water circuit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8

Location of sensors. . . . . . . . . . . . . . . . . . . . . . . .  9

Overall dimensions and water fittings. . . . . . . . .  10

INSTALLER                                                                  11

10 

Unpacking the product . . . . . . . . . . . . . . . . . . . .  11

11 Handling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

12 

Installing the magnesium anodes . . . . . . . . . . . .  13

13 

Fitting the insulation  . . . . . . . . . . . . . . . . . . . . . .  14

14 

Place of installation . . . . . . . . . . . . . . . . . . . . . . .  15

15 

Installation in older systems and systems requiring 

modernisation . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

TECHNICAL ASSISTANCE CENTRE                         16

16 

Putting into service  . . . . . . . . . . . . . . . . . . . . . . .  16

17 

Temporary shutdown. . . . . . . . . . . . . . . . . . . . . .  16

18 

Preparing for extended periods of disuse  . . . . .  16

19 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

20 

Cleaning and removing internal components. . .  17

21 

Recycling and disposal  . . . . . . . . . . . . . . . . . . .  18

22 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . .  18

END USER                                                                  19

23 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  19

24 

Temporary shutdown. . . . . . . . . . . . . . . . . . . . . .  19

25 

Preparing for extended periods of disuse  . . . . .  19

26 

External maintenance . . . . . . . . . . . . . . . . . . . . .  19

Содержание 20052790

Страница 1: ...Installation and Operation Manual Solar solar storage cylinder IDRA N DS Installation and Operation Manual EN...

Страница 2: ...2...

Страница 3: ...by improper installation adjustment maintenance or use RANGE MODEL CODE IDRA N DS 1500 20052790 IDRA N DS 2000 20052791 IDRA N DS 2600 20086803 ACCESSORIES For a complete list of accessories and detai...

Страница 4: ...power switch Drain the central heating circuit and domestic hot water circuit if there is any risk of freezing b This instruction manual is an integral part of the pro duct It must be kept safe and m...

Страница 5: ...20052790K4LH3800001 Model IDRA N DS 1500 Code 20052790 Serial Number K4LH3800001 Beretta Caldaie Via Risorgimento 13 23900 Lecco LC Italy Capacit nom sanitaria 1449 L 1 8 mq 3 4 mq 1200 L h 2200 L h...

Страница 6: ...m2 Top coil heat exchange surface area 1 8 2 8 3 3 m2 Maximum operating pressure of storage cylinder 8 bar Maximum operating pressure of coils 6 bar Maximum operating temperature 99 C Net weight with...

Страница 7: ...OP mbar 600 500 400 300 200 100 0 0 1000 2000 3000 5000 6000 4000 1500 2600 2000 FLOW RATE l h Pressure drops BOTTOM COIL PRESSURE DROP mbar 1000 900 800 600 400 100 200 300 500 700 0 0 1000 2000 3000...

Страница 8: ...low rate from the solar collector circuit depends on the type and number of collectors installed For further infor mation consult the manual for the collectors b The domestic hot water system MUST INC...

Страница 9: ...e proper water glycol mix Risk of freezing b All piping collectors heat exchangers and other de vices in the circuit must be subjected to proper hy draulic seal testing 8 LOCATION OF SENSORS B IDRA N...

Страница 10: ...1 2 F 1 1 4 F Psc1 Diameter length of boiler sensor socket 1 2 F mm Psc2 Diameter length of boiler sensor socket 1 2 F mm Psr Diameter length of solar controller sensor socket 1 2 F mm RE Sleeve for e...

Страница 11: ...ep it safe MODELS IDRA N DS 2000 B IDRA N DS storage cylinders come in two separate packages The first contains the painted cylinder protected by a plastic bag and supported on a wooden pallet The sec...

Страница 12: ...equipment and use suitable safety devices b Make sure that any lifting equipment is of adequate capacity to lift and move the storage cylinder a Do not dispose of packaging material into the envi ron...

Страница 13: ...storage cylinder from the pallet cut the straps secure the lifting cables to the lifting points on the top of the storage cylinder carefully lift the storage cylinder and position it as re quired 12...

Страница 14: ...npack all the material from the second package Wrap the insulation 3 around the storage cylinder carefully lining up the fittings with the holes on the inside of the insulation Secure the insulation i...

Страница 15: ...orage cylinder is to be installed 15 INSTALLATION IN OLDER SYSTEMS AND SYSTEMS REQUIRING MODERNISATION When installing B IDRA N DS storage cylinders in old systems or systems requiring modernisation a...

Страница 16: ...ion Make sure that all circuits have been bled Make sure that the boiler and solar collectors con nected to the system shut down correctly when their mains power switches are turned OFF Provided the a...

Страница 17: ...cylinder after cleaning it a Do not use abrasive products petrol or triethylene INTERNAL CLEANING Removing and checking the magnesium anode Remove the cap 1 cover 2 and the anode insula tor disc 1 2 U...

Страница 18: ...functioning Check the pump The water temperature from the boiler is too low Check the temperature setting There is air in the primary circuit Bleed the circuit SOLAR COLLECTOR CIRCUIT FAULT CAUSE SOLU...

Страница 19: ...t on the environment and save energy before leaving for the weekend or a short break etc pro vided outdoor temperatures will remain above ZERO sim ply adjust the storage cylinder s thermostat to its m...

Страница 20: ...boilers com Beretta reserves the right to modify the characteristics and specifications given in this publication at any time and without prior notice as part of its policy of continuous product impro...

Отзывы: