background image

16

TECHNICAL ASSISTANCE CENTRE

16  PUTTING INTO SERVICE

It is essential to perform the following checks before star-

ting up or testing the functioning of the storage cylinder. In 

particular, check that:

-  The supply cocks in the domestic water circuit are 

all open

-  The water connections to the boiler and solar collec-

tors have been made correctly

-  All the pipes in the water circuit have been insulated 

in conformity to relevant standards

-  The electrical connections of all accessories have 

been made correctly

-  The solar collector circuit has been correctly flushed 

out and filled with water-glycol mix, and all air has 

been bled out of the circuit (see the manual for the 

solar collectors)

-  Start up the boiler (if installed) as instructed in its own 

manual.

-  Put the solar collectors into service. See the manuals 

for the solar collectors and associated accessories.

Once the system has been started up, perform the fol-

lowing checks.

-  Make sure that all pumps are free and rotate in the 

right direction

-  Make sure that all circuits have been bled.

-  Make sure that the boiler and solar collectors con-

nected to the system shut down correctly when their 

mains power switches are turned OFF.

Provided the above checks have been completed satisfac-

torily, restart the system and verify its performance.

17  TEMPORARY SHUTDOWN

If you are going away for a short period of time like a we-

ekend or a short holiday, etc., and outdoor temperatures 

are going to remain above ZERO, proceed as follows.

-  Adjust the storage cylinder thermostat to its minimum 

setting.

If outdoor temperature may drop below ZERO (risk 

of freezing) perform the operations described in the 

“Preparing for extended periods of disuse” section.

18  PREPARING FOR EXTENDED 

PERIODS OF DISUSE

If the storage cylinder is not going to be used for an exten-

ded period of time, perform the following operations:

-  Switch the electricity supply to the storage cylinder’s 

valve group and to any associated boiler OFF at the 

main switch and at the control panel

-  Close the shut-off cocks for the domestic hot water 

circuit.

Drain the central heating circuit and domestic hot wa-

ter circuit if there is any risk of freezing.

Technical Assistance Centre

Содержание 20052790

Страница 1: ...Installation and Operation Manual Solar solar storage cylinder IDRA N DS Installation and Operation Manual EN...

Страница 2: ...2...

Страница 3: ...by improper installation adjustment maintenance or use RANGE MODEL CODE IDRA N DS 1500 20052790 IDRA N DS 2000 20052791 IDRA N DS 2600 20086803 ACCESSORIES For a complete list of accessories and detai...

Страница 4: ...power switch Drain the central heating circuit and domestic hot water circuit if there is any risk of freezing b This instruction manual is an integral part of the pro duct It must be kept safe and m...

Страница 5: ...20052790K4LH3800001 Model IDRA N DS 1500 Code 20052790 Serial Number K4LH3800001 Beretta Caldaie Via Risorgimento 13 23900 Lecco LC Italy Capacit nom sanitaria 1449 L 1 8 mq 3 4 mq 1200 L h 2200 L h...

Страница 6: ...m2 Top coil heat exchange surface area 1 8 2 8 3 3 m2 Maximum operating pressure of storage cylinder 8 bar Maximum operating pressure of coils 6 bar Maximum operating temperature 99 C Net weight with...

Страница 7: ...OP mbar 600 500 400 300 200 100 0 0 1000 2000 3000 5000 6000 4000 1500 2600 2000 FLOW RATE l h Pressure drops BOTTOM COIL PRESSURE DROP mbar 1000 900 800 600 400 100 200 300 500 700 0 0 1000 2000 3000...

Страница 8: ...low rate from the solar collector circuit depends on the type and number of collectors installed For further infor mation consult the manual for the collectors b The domestic hot water system MUST INC...

Страница 9: ...e proper water glycol mix Risk of freezing b All piping collectors heat exchangers and other de vices in the circuit must be subjected to proper hy draulic seal testing 8 LOCATION OF SENSORS B IDRA N...

Страница 10: ...1 2 F 1 1 4 F Psc1 Diameter length of boiler sensor socket 1 2 F mm Psc2 Diameter length of boiler sensor socket 1 2 F mm Psr Diameter length of solar controller sensor socket 1 2 F mm RE Sleeve for e...

Страница 11: ...ep it safe MODELS IDRA N DS 2000 B IDRA N DS storage cylinders come in two separate packages The first contains the painted cylinder protected by a plastic bag and supported on a wooden pallet The sec...

Страница 12: ...equipment and use suitable safety devices b Make sure that any lifting equipment is of adequate capacity to lift and move the storage cylinder a Do not dispose of packaging material into the envi ron...

Страница 13: ...storage cylinder from the pallet cut the straps secure the lifting cables to the lifting points on the top of the storage cylinder carefully lift the storage cylinder and position it as re quired 12...

Страница 14: ...npack all the material from the second package Wrap the insulation 3 around the storage cylinder carefully lining up the fittings with the holes on the inside of the insulation Secure the insulation i...

Страница 15: ...orage cylinder is to be installed 15 INSTALLATION IN OLDER SYSTEMS AND SYSTEMS REQUIRING MODERNISATION When installing B IDRA N DS storage cylinders in old systems or systems requiring modernisation a...

Страница 16: ...ion Make sure that all circuits have been bled Make sure that the boiler and solar collectors con nected to the system shut down correctly when their mains power switches are turned OFF Provided the a...

Страница 17: ...cylinder after cleaning it a Do not use abrasive products petrol or triethylene INTERNAL CLEANING Removing and checking the magnesium anode Remove the cap 1 cover 2 and the anode insula tor disc 1 2 U...

Страница 18: ...functioning Check the pump The water temperature from the boiler is too low Check the temperature setting There is air in the primary circuit Bleed the circuit SOLAR COLLECTOR CIRCUIT FAULT CAUSE SOLU...

Страница 19: ...t on the environment and save energy before leaving for the weekend or a short break etc pro vided outdoor temperatures will remain above ZERO sim ply adjust the storage cylinder s thermostat to its m...

Страница 20: ...boilers com Beretta reserves the right to modify the characteristics and specifications given in this publication at any time and without prior notice as part of its policy of continuous product impro...

Отзывы: