EN / CZone® Contact 6 PLUS User & Installation Manual
10
INSERTING FUSES
The Contact 6 PLUS provides ignition protected circuit protection for each individual channel via standard ATC fuses
(not supplied). Appropriately rated fuses should be selected and installed for each channel to protect the load and the
wiring for each circuit.
Fuses In Normal Operation
1. Select the appropriate fuse rating for each individual circuit.
2. Insert the correctly rated fuses into the NORMAL (bottom) position of all circuits.
3.
The ATC fuse should be rated to protect the connected load and the wiring from the Contact 6 PLUS to the
load and also the ground wire.
MECHANICAL BYPASS
The Contact 6 PLUS includes a mechanical bypass feature for redundancy purposes. Moving any fuse to the BYPASS
(top) position will supply constant battery power to that output. See below diagram showing circuit #3 in the BYPASS
position.
Fuse in Bypass Position
WARNING
–
Ensure area is free of explosive gasses before removing/replacing fuses or placing fuses in the
bypass position as sparks may occur.