2.Connect the lines with the LCD board.
3.Connect the LCD board into the wall plate.
Wifi Series Touch Screen Thermostat
XIII. Attention
Our Service:
We offer the warranty of 24 months from the sales day.
During the warranty, if it is belong to the quality issue, we will fix or replace
by free after testing.
If it is not quality problem or beyond the warranty time, we will charge for
the after-sales service.
Model
TGT70WIFI-AC4
TGT70WIFI-AC2
Thermostat
User Manual
Screws
√
√
√
√
√
√
4.Time Switch
Press 2 seconds to enter into time switch working, you will find bellows:
Loop: Ex
ec
..
My Thermostat
Week Setting:
Time on setting 1:
8:00
Time off setting 1:
11:31
Time on setting 2:
12:32
Time off setting 2:
17:03
07 59
8 : 00
09 01
Cancel Ok
You can set 4 time on/off period. For example,
For example:
Thermostat start working automatically from 8:00am-----11:31am
8:00am time-on, 11:31am time-off.(first time switch circle)
Choose loop mode
Execute once
12345
123456
1234567
Choose loop mode
Execute once: It means temporary Time on/off for a short time. (serval hours or a day)
12345: It means time on/off setting, from Monday-Friday the same.
123456: It means time on/off setting, from Monday-Saturday the same.
123457: It means time on/off setting, from Monday-Sunday the same.
Week setting
5.Working mode
Press on the app, you will find 3 working mode for choose.
Control mode
Ventilation
Cool
Heat
Cancel
<
Press for 2 seconds, you will enter into Advanced setting.
5. Senior(Advanced setting)
Setting dif(dif):
<
My Thermostat
Max temp in cooling(sh1):
1.0
℃
40
℃
Min temp in cooling(sh1):
10
℃
Max temp in heating(sh2):
Min temp in heating(sh2):
Temp compensation(adj):
Fan mode(fan):
Anti-freeze function(fre):
Key lock(loc):
40
℃
10
℃
0
℃
fan coil In-control
Off
Unlock
dif=deadzone/ hysteresis
for room temp.
Eg, Set=22
℃,
dif
=
1
℃,
in cooling mode.
When temp drop to 21
℃,
the
relay
stop
outputing.
When temp up to 22
℃,
relay output again and cooling
SH 1
SL 1
SH 2
SL 2
Fan Coil Controlling Mode Setting
(You can select the fan coil In control & Out-of-control.)
In “F00” mode, when room temp reaches to the setted temp, the fan coil stops working.
In “F01” mode, when room temp reaches to the setted temp, the fan coil goes on working.
FAN
dIF
FRE
Anti-freeze function On, when outage, or power-off state, it keep the room temp
between 5-7
℃
to
protect
your
room Especially for heating mode when in cold weather.
.
LOC
Lock the button for thermostats. 3 choice:
01: button unlock.
02: lock all button except power on/off button.
03: lock all button.
XI. Attention to Phone WiFi Connection:
01.The first time connection, please confirm your mobile phone is WLAN mode,
and ensure the (mobile data) 3G/4G turned off.
After you press Configure, if connection fails, please check the bellowings:
Please connect to 2.4G WIFI, not 5G WIFI.
02.Please add your WIFI router name, we recommend it does not include space.
03.Please check WIFI router password. We recommend < 32 characters,
no spaces, no blank password, no special symbols except letters and numbers.
04.Please check module is successfully reset . (operate as instruction)
In power-off state, Find FAC mode, make FAC=10 or 32, then turn off......
05.Please confirm WIFI password is correctly filled.
We recommend your WIFI password displayed, thus to check password easily.
XII. Installation Instruction
The products suits for standard 80*80mm wall box or 60mm Europe round box.
1.Connect the line of power and valve into the terminals.
Fix the wall plate into the wall box by a screwdrive.
Please read this manual for complete instructions on installing and
operating your thermostat. If you require further assistance, please
feel free to contact us.
In the box you will find:
Thank you for buying this product!
RoHS
When thermostat temp differs from the real temp,
you can do some calibration.
Calibration range -5~5
℃
AdJ
4