TECHNICAL DATA
172 215 43 07-01
Capacity chart according
to EN 676
1
) Calorific value:
Natural gas 10 kWh/Nm
3
2
) Depending on gas quality and
available pressure
Out range
The above dimensions are max. measurements. Depending on the compo
-
nents used, the measurements may vary.
Type
Capacity
Nm
3
/h at min.
output of burner
1
)
Nm
3
/h at max
output of burner
1
)
Rated inlet pressures
mbar
STG 146
Natural gas
23,5-65
Natural gas
2,35
Natural gas
6,5
Natural gas
20
Connection
2
)
Motor
Ignition transformer
Natural gas
½"
220/240V,2800r/m,
50Hz, 70-90 W, 0,65A
Electronic
230/11000V, Ampl.
Length of
burner tube
Flange A
Measure A
Standard
108
81
Long design
140
113
Type designation STG 146 Burner head 1
in accordance with RAL UZ 80
Dimensions
A
ø 89
202
61
192
139
290
244
10
145,0
23,5
109,5
Содержание STG 146
Страница 2: ......
Страница 18: ...172 305 50 07 01 GENERAL INSTRUCTIONS Control of burner head Air adjustment Adjustment of inner assembly...
Страница 27: ......
Страница 28: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...