background image

171 505 41  07-01

   

Gph

18

19

20

21

kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h

1,00

4,99

59

51

5,13

61

52

5,26

62

54

5,40

64

55

1,10

5,49

65

56

5,64

67

57

5,79

69

59

5,93

70

60

1,20

5,99

71

61

6,16

73

63

6,32

75

64

6,47

77

66

1,25

6,24

74

64

6,41

76

65

6,58

78,

67

6,74

80

69

1,35

6,74

80

69

6,93

82

71

7,11

84

72

7,28

86

74

1,50

7,48

89

76

7,69

91

78

7,89

93

80

8,08

96

82

1,65

8,24

98

84

8,47

100

86

8,69

103

89

8,90

105

91

1,75

8,78

104

90

8,98

106

92

9,21

109

94

9,44

112

96

2,00

9,99

118

102

10,26

122

105

10,53

125

107

10,79

128

110

2,25 11,24

133

115

11,55

137

118

11,85

140

121

12,14

144

124

2,50 12,48

148

127

12,83

152

131

13,16

156

134

13,49

160

138

2,75 13,73

163

140

14,11

167

144

14,48

171

148

14,84

176

151

3,00 14,98

178

153

15,39

182

157

15,79

187

161

16,18

192

165

3,50 17,48

207

178

17,96

213

183

18,43

218

188

18,89

224

193

4,00 19,98

237

204

20,53

243

209

21,06

250

215

21,59

256

220

4,50 22,47

266

229

23,09

274

235

23,69

281

242

24,28

288

248

5,00 24,97

296

255

25,65

304

262

26,33

312

268

26,98

320

275

5,50 27,47

326

280

28,22

335

288

28,96

343

295

29,68

352

303

6,00 29,97

355

306

30,79

365

314

31,59

374

322

32,38

384

330

6,50 32,46

385

331

33,35

395

340

34,22

406

349

35,07

416

358

7,00 34,96

415

356

35,92

426

366

36,86

437

376

37,77

448

385

7,50 37,46

444

382

38,49

456

392

39,49

468

403

40,47

480

413

8,00 39,96

474

407

41,05

487

419

42,12

499

429

43,17

512

440

8,50 42,45

503

433

43,62

517

445

44,75

531

456

45,87

544

468

9,00 44,95

533

458

46,18

548

471

47,39

562

483

48,57

576

495

9,50 47,45

563

484

48,75

578

497

50,02

593

510

51,26

608

523

10,00 49,94

592

509

51,32

609

523

52,66

624

537

53,96

640

550

11,00 54,94

652

560

56,45

669

576

57,92

687

591

59,36

704

605

12,00 59,93

711

611

61,58

730

628

63,19

749

644

64,76

768

660

14,00 69,92

829

713

71,84

852

733

73,72

874

752

75,55

896

770

16,00 79,91

948

815

82,11

974

837

84,25

999

859

86,34 1024

880

NOZZLE TABLE

Pump pressure bar

The table applies to oil with a viscosity of 4,4 mm

2

/s (cSt) with density 830 kg/m

3

.

1(2)

Содержание B 45 A2.2H

Страница 1: ...Providing sustainable energy solutions worldwide 178 014 56 2014 11 11 Installation and maintenance instruction B 45 A2 2H...

Страница 2: ......

Страница 3: ...e 2 15 Solenoid valves 16 Nozzle assembly adjustment 17 Connecting pipe pump adjustment device 18 Adjustment device Nozzle assembly adjustment 19 Fuse 20 Indicating lamp Stage 2 21 Switch I II 22 Indi...

Страница 4: ...and the spray pattern change with the pump pressure Output range and nozzles recommended The net calorific value of 11 86 kWh kg for light oil has been used Length of burner tube Flange Measure B B45A...

Страница 5: ...TECHNICAL DATA 171 225 34 09 01 Dimensions of flange 14 134 200 224 260...

Страница 6: ...optimum adjust ment is obtained If larger nozzles are used the preadjustment of both the air volume and the nozzle assembly must be increased A whistling sound may be heard which can be eliminated or...

Страница 7: ...stage Set the operating switch S2 on low capacity I Loosen the screw A and turn the damper to the position wan ted Tighten the screw A again Second stage Set the operating switch S2 on high capacity...

Страница 8: ...and cut off the oil supply Service of burner head alt A Service of burner head alt B Note For maintenance of the brake plate nozzles electrodes etc when using a long design of the burner tube you have...

Страница 9: ...l burner control LMO24 255 Wiring diagram ELECTRIC EQUIPMENT 1 3 1N 50 60 Hz 230 V If the boiler is not equipped with wired contacts connect the enclosed contacts to terminals X4 and X6 in accordance...

Страница 10: ...es and the solenoid valve 1 opens 2 2 Solenoid valve 1 opens Oil mist is formed and ignited The photocell indicates a flame 3 The safety time expires a If no flame is established before this time limi...

Страница 11: ...blem by pressing and holding the reset button for 3 seconds The number of flashes below is repeated with a pause in between 2 flashes No flame signal when safety time expires 4 flashes False light dur...

Страница 12: ...length in metres at a nozzle capacity of 9 5 Gph Max permissible pres sure at the suction and pressure side is 2 0 bar Components 1 Nozzle outlet G 1 8 Stage 2 2 Pressure gauge port G 1 8 3 Nozzle ou...

Страница 13: ...ic it is assured by a bleed flat on the piston In one pipe operation a high pressure connection must be loosened until the air is evacuated from the system Cut Off The solenoid valves of the A2L pump...

Страница 14: ...93 9 71 115 99 10 24 121 104 10 73 127 109 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14...

Страница 15: ...1 21 133 114 11 67 138 119 12 11 144 123 12 53 148 128 3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 9...

Страница 16: ...23 34 277 238 6 00 22 34 265 228 23 42 278 239 24 47 290 250 24 46 302 260 6 50 24 20 287 247 25 37 301 259 26 51 314 270 27 58 327 281 7 00 26 06 309 266 27 33 324 279 28 55 339 291 29 70 352 303 7 5...

Страница 17: ...70 317 272 6 00 26 43 313 270 27 49 326 280 28 27 335 288 29 13 345 297 6 50 28 63 340 292 29 63 351 302 30 62 363 312 31 55 374 322 7 00 30 84 366 314 31 91 378 325 32 98 391 336 33 98 403 374 7 50 3...

Страница 18: ...9 256 220 4 50 22 47 266 229 23 09 274 235 23 69 281 242 24 28 288 248 5 00 24 97 296 255 25 65 304 262 26 33 312 268 26 98 320 275 5 50 27 47 326 280 28 22 335 288 28 96 343 295 29 68 352 303 6 00 29...

Страница 19: ...3 56 279 240 4 50 24 85 295 253 25 41 301 259 25 96 308 265 26 49 314 270 5 00 27 61 327 282 28 24 335 288 28 84 342 294 29 44 349 300 5 50 30 38 360 310 31 06 368 317 31 73 376 324 32 38 384 330 6 00...

Страница 20: ...magnetic valve Burner fails to start Lamp not lit Motor runs Burner runs to lockout Fuse has blown Appliance thermostat has not reset Appliance overheat device has operated Control relay or photocell...

Страница 21: ...nt conformes aux normes et aux documents normatifs suivants et satisfont aux crit res applicables des directives CE suivantes Dokument EN 267 EN 60335 EU direktiv EU Directives EU Direktiven CE suivan...

Страница 22: ...the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If...

Страница 23: ......

Страница 24: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...

Отзывы: