171 505 40  07-01

   

Gph

10

11

12

13

kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h

1,00

3,72

44

38

3,90

46

40

4,08

48

42

4,24

50

43

1,10

4,09

48

42

4,29

51

44

4,48

53

46

4,67

55

48

1,20

4,47

53

46

4,68

55

48

4,89

58

50

5,09

60

52

1,25

4,65

55

47

4,88

58

50

5,10

60

52

5,30

63

54

1,35

5,02

59

51

5,27

62

54

5,50

65

56

5,73

68

58

1,50

5,58

66

57

5,85

69

60

6,11

72

62

6,36

75

65

1,65

6,14

73

63

6,44

76

66

6,73

80

69

7,00

83

71

1,75

6,51

77

66

6,83

81

70

7,14

85

73

7,42

88

76

2,00

7,45

88

76

7,81

93

80

8,16

97

83

8,49

101

87

2,25

8,38

99

85

8,78

104

90

9,18

109

94

9,55

113

97

2,50

9,31

110

95

9,76

116

100

10,19

121

104

10,61

126

108

2,75 10,24

121

104

10,73

127

109

11,21

133

114

11,67

138

119

3,00 11,16

132

114

11,71

139

119

12,23

145

125

12,73

151

130

3,50 13,03

154

133

13,66

162

139

14,27

169

146

14,85

176

151

4,00 14,89

176

152

15,62

185

159

16,31

193

166

16,97

201

173

4,50 16,75

199

171

17,57

208

179

18,35

218

187

19,10

226

195

5,00 18,62

220

190

19,52

231

199

20,39

242

208

21,22

252

216

5,50 20,48

243

209

21,47

255

219

22,43

266

229

23,34

277

238

6,00 22,34

265

228

23,42

278

239

24,47

290

250

24,46

302

260

6,50 24,20

287

247

25,37

301

259

26,51

314

270

27,58

327

281

7,00 26,06

309

266

27,33

324

279

28,55

339

291

29,70

352

303

7,50 27,92

331

285

29,28

347

299

30,59

363

312

31,83

377

325

8,00 29,79

353

304

31,23

370

318

32,63

387

333

33,95

403

346

8,50 31,65

375

323

33,18

393

338

34,66

411

353

36,07

428

368

9,00 33,59

398

343

35,14

417

358

63,71

435

374

38,19

453

389

9,50 35,37

419

361

37,09

440

378

38,74

549

395

40,31

478

411

10,00 37,23

441

380

39,04

463

398

40,78

484

416

42,44

503

433

11,00 40,96

486

418

42,94

509

438

44,86

532

457

46,68

554

476

12,00 44,68

530

456

46,85

556

478

48,94

580

499

50,92

604

519

14,00 52,12

618

531

54,65

648

557

57,10

677

582

59,41

705

606

16,00 59,57

706

607

62,46

741

637

65,26

774

666

67,90

805

692

18,00 67,02

795

683

70,27

833

717

73,41

871

749

76,39

906

779

20,00 74,47

883

759

78,08

926

796

81,57

967

832

84,87 1007

865

22,00 81,91

971

835

85,89 1019

876

89,73 1064

915

93,36 1107

952

24,00 89,36

1060

911

93,70

1111

956

97,88 1161

998

101,85 1208

1039

26,00 96,81

1148

987

101,50 1204

1035

106,04 1258

1081

110,33 1308

1168

NOZZLE TABLE

Pump pressure bar

The table applies to oil with a viscosity of 4,4 mm

2

/s (cSt) with density 830 kg/m

3

.

1(2)

Содержание B 45 A2.2H

Страница 1: ...Providing sustainable energy solutions worldwide 178 014 56 2014 11 11 Installation and maintenance instruction B 45 A2 2H...

Страница 2: ......

Страница 3: ...e 2 15 Solenoid valves 16 Nozzle assembly adjustment 17 Connecting pipe pump adjustment device 18 Adjustment device Nozzle assembly adjustment 19 Fuse 20 Indicating lamp Stage 2 21 Switch I II 22 Indi...

Страница 4: ...and the spray pattern change with the pump pressure Output range and nozzles recommended The net calorific value of 11 86 kWh kg for light oil has been used Length of burner tube Flange Measure B B45A...

Страница 5: ...TECHNICAL DATA 171 225 34 09 01 Dimensions of flange 14 134 200 224 260...

Страница 6: ...optimum adjust ment is obtained If larger nozzles are used the preadjustment of both the air volume and the nozzle assembly must be increased A whistling sound may be heard which can be eliminated or...

Страница 7: ...stage Set the operating switch S2 on low capacity I Loosen the screw A and turn the damper to the position wan ted Tighten the screw A again Second stage Set the operating switch S2 on high capacity...

Страница 8: ...and cut off the oil supply Service of burner head alt A Service of burner head alt B Note For maintenance of the brake plate nozzles electrodes etc when using a long design of the burner tube you have...

Страница 9: ...l burner control LMO24 255 Wiring diagram ELECTRIC EQUIPMENT 1 3 1N 50 60 Hz 230 V If the boiler is not equipped with wired contacts connect the enclosed contacts to terminals X4 and X6 in accordance...

Страница 10: ...es and the solenoid valve 1 opens 2 2 Solenoid valve 1 opens Oil mist is formed and ignited The photocell indicates a flame 3 The safety time expires a If no flame is established before this time limi...

Страница 11: ...blem by pressing and holding the reset button for 3 seconds The number of flashes below is repeated with a pause in between 2 flashes No flame signal when safety time expires 4 flashes False light dur...

Страница 12: ...length in metres at a nozzle capacity of 9 5 Gph Max permissible pres sure at the suction and pressure side is 2 0 bar Components 1 Nozzle outlet G 1 8 Stage 2 2 Pressure gauge port G 1 8 3 Nozzle ou...

Страница 13: ...ic it is assured by a bleed flat on the piston In one pipe operation a high pressure connection must be loosened until the air is evacuated from the system Cut Off The solenoid valves of the A2L pump...

Страница 14: ...93 9 71 115 99 10 24 121 104 10 73 127 109 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14...

Страница 15: ...1 21 133 114 11 67 138 119 12 11 144 123 12 53 148 128 3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 9...

Страница 16: ...23 34 277 238 6 00 22 34 265 228 23 42 278 239 24 47 290 250 24 46 302 260 6 50 24 20 287 247 25 37 301 259 26 51 314 270 27 58 327 281 7 00 26 06 309 266 27 33 324 279 28 55 339 291 29 70 352 303 7 5...

Страница 17: ...70 317 272 6 00 26 43 313 270 27 49 326 280 28 27 335 288 29 13 345 297 6 50 28 63 340 292 29 63 351 302 30 62 363 312 31 55 374 322 7 00 30 84 366 314 31 91 378 325 32 98 391 336 33 98 403 374 7 50 3...

Страница 18: ...9 256 220 4 50 22 47 266 229 23 09 274 235 23 69 281 242 24 28 288 248 5 00 24 97 296 255 25 65 304 262 26 33 312 268 26 98 320 275 5 50 27 47 326 280 28 22 335 288 28 96 343 295 29 68 352 303 6 00 29...

Страница 19: ...3 56 279 240 4 50 24 85 295 253 25 41 301 259 25 96 308 265 26 49 314 270 5 00 27 61 327 282 28 24 335 288 28 84 342 294 29 44 349 300 5 50 30 38 360 310 31 06 368 317 31 73 376 324 32 38 384 330 6 00...

Страница 20: ...magnetic valve Burner fails to start Lamp not lit Motor runs Burner runs to lockout Fuse has blown Appliance thermostat has not reset Appliance overheat device has operated Control relay or photocell...

Страница 21: ...nt conformes aux normes et aux documents normatifs suivants et satisfont aux crit res applicables des directives CE suivantes Dokument EN 267 EN 60335 EU direktiv EU Directives EU Direktiven CE suivan...

Страница 22: ...the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If...

Страница 23: ......

Страница 24: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...