34
Bentone
!
When servicing/replacing components that affect combustion,
flue gas analysis and soot test must be carried out following
installation.
165 105 11-3
7.8
Replacement of electrical components
1.
Disconnect the main power and switch off the fuel supply.
2.
Note the connection of the existing component and disassemble.
3.
Fit new component with same connection or with specified alternative
connection.
4.
Switch on the main power and check the operation of the new
component.
5.
Start burner and check/adjust combustion.
!
Before obtaining access to terminals,
all supply circuits must be disconnected.