IMPORT DATA program
This program is installed together with the Central Station program. It is ex-
tremely useful as it imports the relevant Omnia or NormaCom customer
data without requiring manual copying.
To import the relevant Omnia or NormaCom customer data, startup Import
Data and proceed as follows.
Ø
Select the source and destination of the data.
In the
Data Omnia NormaCom in
field, specify the
DATA
folder present
on the working folder of the
Bentel Omnia-NormaCom
group programs:
the program displays C:\BENTEL\DATA, in order to select another folder
click on [Browse].
Ø
In the
Central Station Data in
field, it is necessary to specify the working
folder of the
Bentel Central Station
group: the program displays C:\BEN-
TELCS; to select another folder click on [Browse].
Ø
In the
Panel type
field, indicate the type of panel (NormaCom or Omnia),
of the customer.
If the origin of the data is correct, the program will display the list of cus-
tomers with this type of control panel.
Ø
Select the customer to import: the program will display the Central Stations
that the control panel is programmed to call (see the
Central Station to
transfer
table).
Ø
Select the Central Station source and then click on [Go].
+
If an attempt to import an existing customer is made, the program displays
an error message <<Client already exists in the Bentel Central Station>>.
Import Data will create a new customer in the Central Station, with a code
starting with the letter "P", followed by the Customer Code programmed in
Omnia or NormaCom and will also import the following information:
Ø
personal details of the customer selected (see
Name, Address, Tele-
phone Number, Installation Description
fields of the "Customer" sheet);
Ø
data relevant to the Pulse communicator Actions that activate the calls to
Central Stations selected (the
Event code
and
Description
of the Action
become respectively the
Event Code
and
Event
in the Central Station, the
Description
of the events that activate the Action become the event
De-
scription
in the Central Station).
+
If the action of the Pulse communicator is not activated by any event, Im-
port Data will not create any event for it.
If the action of the Pulse communicator is activated by several events, the
corresponding event Type will be determined by the first event on the list.
IMPORT DATA program
25
Содержание OmniaMOD-V2
Страница 1: ......
Страница 9: ...Figure 1 Parts identification and installation of the OmniaMOD V2 modem ...
Страница 24: ...Figure 3 Working diagram for Import Data with NormaCom customer 24 Central Station OmniaMOD V2 ...
Страница 27: ...Figure 4 Working diagram for Import Data with Omnia customer ...
Страница 28: ......