background image

16

LTCA

During the TCA time, the blinker is enabled or disabled.
On: Enables blinker.
Off: Disables blinker.

(OFF)

CVAR

The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Off: Receiver enabled for rolling-code and programmable code 
transmitters (self-learning and Dip Switch).

(OFF)

SOFT

Soft start is enabled or disabled. 
On: Starting is performed at reduced speed for 2s and then movement is 
restored to normal speed. 
Off: Soft start is disabled. 

(ON)

INvA

The movement reversion during opening after the activation of the anti-
crash device (amperometric sensor) is enabled or disabled.
On: enabled reversion. The amperometric sensor activation causes the 
movement reversion.
Off: disabled reversion. The amperometric sensor activation causes the 
movement stop.

(OFF)

SASO

Enables or disables door stop  before the opening mechanical stop 
ON:  The  control  unit  stops  the  door  around  5  cm  before  the  mechanical 
stop. 
In this way  stop is progressive and without vibrations.
OFF: The control unit stops the door on  the opening mechanical stop 

(OFF)

tst1

The photocell checks are activated or deactivated. Before the closing ope-
ration, the control unit checks the switching of the photocell contact. If the 
checks are not successful, the door will not close.
On: activated check on photocell
Off: deactivated  check on photocell

(OFF)

esa

5IFi&4"wFOFSHZTBWJOHTGVODUJPOJTBDUJWBUFEPSEFBDUJWBUFE

On: Enabled energy savings. After around 10 sec of non-operation, the po-
wer supply is cut off from the accessory output and the system switches to 
stand-by.
Off: Disabled energy savings. This is to be used should the accessory power 
supply output is to be always activated, e.g. if keypads powered at 24VDC 
or other devices that need to be always powered, are used. 

(ON)

REM

The remote storage of the radio transmitter codes is enabled or disabled (see 
par. REMOTE LEARNING).
On: Enabled remote storage 
Off: Disabled remote storage.

(OFF)

RADIO (

RAD

)

MENU

FUNCTION

PP

By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the step-
by-step function.
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.

2Ch

By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the second 
radio channel.
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.

Sair

When this function is selected, the receiver awaits (Push) a transmitter code to be assigned to the SAIR 
function (see SAIR parameter).
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.

Содержание CP.J4 ESA

Страница 1: ...L8542920 04 2011 rev 0 CP J4 ESA UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI...

Страница 2: ...00mA max 24Vac dc SCA Service Light R A D I O F1 T A COM P P STOP PHOT OPEN CLOSE BAR BAR SCA SCA BLINK BLINK 24V 24V N L F2 1AT 230V F2 2AT 115V MOT L1 AUX N1 L1 N1 0V OUT ENC M M ENC ANT ANT SHIELD...

Страница 3: ...BLINK BLINK 24V 24V 8K2 4 2 3 SCA AUX1 0 BAR BAR SCA SCA BLINK BLINK 24V 24V SCA 24Vac 3W max 24Vac 1A max AUX1 1 II CH RADIO BAR BAR SCA SCA BLINK BLINK 24V 24V AUX1 2 SERVICE ZONE LIGHT Service Lig...

Страница 4: ...ssential characteristics of the product unchanged the manufacturer reserves himself the right to bring any change of technical constructive or commercial character without undertaking himself to updat...

Страница 5: ...push button Normally Open contact A timer clock can be connected for openings according to timeframes PHOT Photocell Input photocell is activated in the closing phase STOP STOP STOP button input N C...

Страница 6: ...red values in the programming menus described below The parameters menu allows you to assign a numerical value to a function in the same way as a regulating trimmer The logic menu allows you to activa...

Страница 7: ...ion of the opening operation 3 Area light The contact closes in the opening phase and remains closed for the entire TCA time It opens only with closed door 0 3 3 ATTENTION A wrong formulation of these...

Страница 8: ...BWJOHT GVODUJPO JT BDUJWBUFE PS EFBDUJWBUFE On Enabled energy savings After around 10 sec of non operation the po wer supply is cut off from the accessory output and the system switches to stand by Of...

Страница 9: ...paragraph SELF LEARNING PASSWORD CODE It allows to type in an access protection code to the programming of the control unit A four character alphanumeric code can be typed in by using the numbers fro...

Страница 10: ...ring the door leaf stoke If the error occurs during self learning of the radio transmitters this means that the memory of the receiver is no longer able to receive other transmitters or the transmitte...

Отзывы: