Bennett 621 Interconnection Box Instruction & Service Manual
Service Instructions
14
HELPFUL PROGRAMMING HINTS
The following contains basic communication programming procedures for a Bennett Pacific and Nucleus POS. It is
EXTREMELY
important that all of the appropriate Bennett and OEM manuals be reviewed prior to operation.
To enter Manager’s Mode enter the access code
<2218>
and press
<ENTER>
.
To access a specific manager’s mode, enter the mode number and press the <
MODE>
key.
If multiple displays associated with the selected manager’s mode, press the <
DOWN ARROW KEY>
to cycle between
the displays.
To exit a specific manager’s mode and return to the idle manager’s mode, press the
CANCEL
key.
BENNETT PACIFIC PROGRAMMING
In order to function properly, the following settings
MUST
be programmed at the dispenser to communicate with the Nucleus®.
NUCLEUS PROGRAMMING
In order for the Bennett dispensers to function properly, the correct settings must be made in the pump-programming window
of the Nucleus system. Three settings in the “
Pump Options
” window will need to be programmed correctly in order for the
dispensers to function. These settings are TYPE, PUSH TO START, and VALID POSITIONS. Other settings in this window will not
inhibit dispenser operation.
Note:
Please refer to the appropriate Nucleus programming guide for complete programming
instructions.
PACIFIC CONFIGURATION
DISPENSER TYPE
PUSH-TO-START
VALID POSITIONS / GRADE MAPPING
Three Product Blender
VRB
None or Select Grade
3-High Grade, 5-Blend, 7-Low Grade
3+1 Blender
VRB Plus
None or Select Grade
1-Diesel, 4-High Grade, 5-Blend, 6-Low Grade
Three Grade Mixer
MGD Uni-Hose
None or Select Grade
1-Grade A, 2-Grade B, 3-Grade C
One Grade Non-Blender
MGD Uni-Hose
None or Select Grade
1-Grade A
Two-Grade Non-Blender
MGD Multi-Hose
None or Select Grade
1-Grade A, 2-Grade B
Three Grade Non-Blender
MGD Multi-Hose
None or Select Grade
1-Grade A, 2-Grade B, 3-Grade C
MODE
DESCRIPTION
SETTING
NOTES
21
Communication Type
3 = Generic Current Loop
Display will read “
generic Loop
”
22
Dispenser Address
Site Specific
Set a unique address for each fueling position. The
display will read “
Generic adr
xx
” where “
xx
”
will be the current address for the specific fueling
position. Each fueling position may have an address
from 1-24. Each fueling position must be connected to
the appropriate position on the 621 interface board.
The 621 pools each channel on the board in search of
the correct address.
Example:
Channel 1 on the 621
supports address 1 & 2. Channel 2 on the 621 supports
address 3 & 4 and so on.
23
Push-To-Start
0 = Disabled
1 = Enabled
Menu code 23 controls if push-to-start is required. This
mode
must be
programmed to match the push-to-start
field within pump programming in the Nucleus.
99
Unit of Measure
Unit of Measurement
1 = Gallons
2 = Liters
3 = British Imperial Gallons
Decimal Placement
1 = 1000
th
This menu code sets the volume unit of measurement.
Option 1 is for gallons, 2-Liters, 3-British Imperial
Gallons. Press Enter to access decimal location. Option
1 must be set to 1 (1000
th
) for operation with the
Nucleus.
08
Decimal Location
0 = U.S.A.
This menu code controls the decimal placement of the
monetary display values. This mode must always be set
to option 0 for operation with the Nucleus.