background image

Calibration and Operation

Once installation of the XPT System is complete, use the EIC to bleed the system by holding down the “BOW DOWN” position for  
15 seconds, then “BOW UP” for 15-20 seconds. Repeat 3 times. This will purge air from the system. Then place both tabs in the “full 
down” position and check all hydraulic connections for leaks. Bring the tabs to the 

full UP

 position and check the fluid level. Add ATF if 

necessary. Also check for leaks in the “UP” position. 

Calibration

 — 

NOTE:

 

Calibration must be done at the Lower Helm EIC Display

1. 

The port and starboard 

red

 

LEDs will flash alternately, indicating that the system is not  

 

calibrated.  

2. 

Press and hold the “sun” and “moon” buttons on the Lower Helm EIC Display  

 

simultaneously for approximately 3 seconds. Both the port and starboard 

lower

 

yellow

 LEDs  

  

 

will begin to flash. Release the “sun” and “moon” buttons.

3. 

Using the Lower Helm EIC Display, run both trim tabs to the full down position  

 

(BOW DOWN on the control). 

Make sure the tabs go all the way DOWN by holding the buttons  

 

for at least 15 seconds.  

(Holding the buttons after the tabs are down will not harm the system). 

4. 

A few seconds after the tabs are all the way down, the port and starboard 

upper 

yellow

 LEDs will begin flashing. Again,  

 

using the Lower Helm EIC Display, run both tabs to the full up position (BOW UP on the control).

 Make sure the tabs come  

 

all the way UP by holding the buttons for at least 15 seconds.  

5. 

The upper and lower 

yellow

 LEDs will then light up solidly, indicating that the EIC is calibrated and ready to operate. If you   

 

wish to recalibrate the EIC at any time, simply bring the tabs to the full up position, press and hold the “sun” and “moon” 

  

buttons down and repeat the calibration instructions.

Operation

The intensity of the display LEDs may be adjusted by pressing the “sun” button to brighten and the “moon” button to dim the display. 

EIC Display Diagnostic Information

Port and starboard 

red

 LEDs alternately flash: 

EIC requires calibration. Refer to calibration information above.

Upper 

 

yellow

 LED flashes on port or starboard side:

 Indicates the EIC Display is not receiving a sensor signal. If the port upper  

yellow

 LED flashes the fault is in the port sensor or wires. A flashing  

yellow

 LED on the starboard side would indicate a fault on the 

starboard sensor or wires. Switching the sensor connections on the EIC Relay Module will confirm the diagnostic code if the flashing LEDs 
switch sides. If the problem switched sides, check the suspected faulty actuator with an Ohm meter at the EIC sensor cable plug. The 
reading should be in the 220-260 Ohm range. If the sensor readings are good, check for faulty connections (corrosion or broken wires). 

10

Moon Button

Sun Button

Содержание Premier XPT Series

Страница 1: ...eerfield Beach Florida 33442 USA Phone 1 954 427 1400 Fax 1 954 480 2897 IMPORTANT SAFETY INSTRUCTIONS Read instructions completely before beginning installation Test the system before putting the boa...

Страница 2: ...bow and it will produce a larger wake When trimmed the bow spray is farther forward the wake is reduced and the rooster tail is smaller and farther behind the boat You ll also notice that the engine R...

Страница 3: ...each other Stainless steel is not flexible Measurements have to be precise BE CAREFUL NOT TO ROTATE THE ACTUATOR SHAFT ROTATING THE SHAFT WILL DAMAGE THE INTERNAL SENSOR NOTE NOT INTENDED FOR RACING...

Страница 4: ...nipples and sensor plugs through the holes in the transom cover the ends with masking tape to prevent damage or debris from entering the system Carefully insert sensor wire through center hole Pull a...

Страница 5: ...tenscrewsonmountingbracket Step 9 Attaching Fittings Inside the transom remove the protective tape from the pipe nipples Check that the pipe nipples are clean and clear Then applyTeflon tape on male t...

Страница 6: ...tuator Viewfrom Insideof Boat Figure8 StarboardSide ofBoat PortSide ofBoat Tabs Down Tabs Up Tabs Up Tabs Down Tabs Down Tabs Up Starboard DAHPU Starboard Actuators Port DAHPU Port Actuators Figure9 T...

Страница 7: ...g Relay Module RMSTBD12DA 7 EIC Dual Pump Cable Y Harness EICWH10101 8 Dual Acting Hydraulic Power Unit DAHPU Ground 1 EICDisplay 2 3 4 8 5 6 Partsalsoavailablefor24Voltsystems Shortercableshownon 3EI...

Страница 8: ...ug green to green Step 4 Connecting the DAHPU 8 on System Schematic Wire Harnesses to the Port and Starboard Dual Acting Relay Modules Connect the Port DAHPUWire Harness to the Port Dual Acting Relay...

Страница 9: ...elm EIC Display Plug the EIC BridgeWire Harness into ANY of the three connectors on the Bridge Box The cable must be properly strain relieved at both ends to support the weight of the cable at the Bri...

Страница 10: ...m EIC Display run both tabs to the full up position BOW UP on the control Make sure the tabs come all the way UP by holding the buttons for at least 15 seconds 5 The upper and lower yellow LEDs will t...

Страница 11: ...breakers orusedbreakersandinlinefuses Therearefive 5 ground blackwires two 2 DAHPUs two 2 DualActingRelayModulesandone 1 EICRelayModule IftheporttrimtabdoesnotmovewhenDAHPUispowereddirect thentheportD...

Страница 12: ...ration Reaction Touch positive to Red and Blue Simultaneously Port trim tab down Touch positive to Red and Yellow Simultaneously Port trim tab up Touch positive to Green and Blue Simultaneously Starbo...

Страница 13: ...on It represents a 10 degree transom angle Trailing Edge Holes Farthest from theTransom These two hole options create more negative angle and less lift If the bow is too low during sea trial you may w...

Страница 14: ...rim Tab Kits When only the best will do Bennett s exceptional Premier Line Trim Tab systems are your only option With superior design and engineering Premier systems are built to the highest standards...

Страница 15: ...ucts must be sent pre paid together with a copy of the invoice or vessel s bill of sale d In case the repairs are not under warranty as specified in the condition paragraph 2 the owner agrees to pay t...

Страница 16: ......

Отзывы: