26
PSo
The torque applied to the motor during braking in the closing phase is adjusted.*
1-99-(50%)
PSC
The torque applied to the motor during braking in the opening phase is adjusted *
1-99-(50%)
SEAV
The trigger time of the anti-crash device (Encoder) is adjusted during the normal speed phase*.
99: maximum sensitivity – 0: Minimum sensitivity
0-99-(1%)
SEAR
The trigger time of the anti-crash device (Encoder) is adjusted during the braking phase*.
99: maximum sensitivity – 0: minimum sensitivity
0-99-(1%)
TLS
Activated only with
SERL
:ON Logic. The activation time of the service light is adjusted.
1-240-(60s)
ibra
The force of the motor brake is adjusted.
0: disabled braking - 1:minimum braking - 99: maximum braking
0-99-(80%)
blc
Motor stop delay on limit switch. It is activated only with enabled braking (TSM).
The motor stop delay is adjusted after the triggering of the limit switch. Use a value calibrated
on the gate weight. Use these indicative values:
25 very heavy gates (longer delay)
18 heavy gates
10 average gates
1
light gates (short delay)
0
deactivated (no delay)
0-25-(0)
* WARNING:
An incorrect setting of these parameters may result in a danger.
Comply with regulations in force!
LOGICS (
LOG
)
MENU
FUNCTION
DEFAULT
MEMO
TCA
The automatic closure is enabled or disabled
On: enabled automatic closure
Off: disabled automatic closure
(ON)
IbL
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the transmitter
have no effect in the opening phase.
Off: disabled multi-flat function.
(OFF)
IBCA
PP and PED controls are enabled or disable during the TCA phase.
On: PP and PED control units are disabled.
Off: PP and PED control units are enabled.
(OFF)
SCL
The rapid closure is enabled or disabled
On: rapid closure is enabled. When the gate is open or moving, the photocell activation causes
the automatic closure of the gate after 3 s. It is activated only with
TCA
:ON
Off: rapid closure is disabled.
(OFF)
PP
The operating mode of “P.P. Push button” and of the transmitter are selected.
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
(OFF)
PRE
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting of
the motor.
Off: disabled forewarning flashing light.
(OFF)
LTCA
During the TCA time, the blinker is enabled or disabled.
On: Activated blinker.
Off: De-activated blinker.
(OFF)
htr
The Operator function is enabled or disabled.
On: Operator function enabled.
During operation, the OPEN/CLOSE push-buttons must be kept pressed.
Off: Automatic operation.
(OFF)
ENC
The Encoder is enabled or disabled. See section “Operating mode with enabled/disabled En-
coder”
On: Encoder enabled – The anti-crash sensor is activated.
Off: Encoder disabled – The anti-crash sensor is deactivated.
(ON)
Cvar
Enables or disables the programmable code transmitters.
IMPORTANT: The transmitters with programmable code can only be used in conjunction with the
Rolling Code HCS transmitters.
On: Radio receiver enabled only for transmitters Rolling Code (ARC or HCS, the first transmitter
sets the operating mode).
Off: Receiver enabled for transmitters Rolling Code HCS and programmable (self-learning and
dip/switch).
(ON)
Содержание YAK 20 OM 115
Страница 2: ...2 ...
Страница 3: ...3 1 2 325 250 570 195 149 A B 143 33 3 3 5 m m 2 2 0 m m 7 0 m m 5 0 m m C ...
Страница 4: ...4 3 4 B F T V Z R ...
Страница 5: ...5 5 7 2 mm 6 P S M C ...
Страница 6: ...6 8 11 9 10 GND L N C L ...
Страница 7: ...7 12 A S 1 3 cm F 8 7 4 1 2 3 3 x 1 5 min 2 x 1 5 RG 58 5 4 x 0 35 230V 4 6 5 2 x 0 35 3 x 0 35 13 OK ...
Страница 11: ...11 OPEN OPEN OPEN OPEN MINV On MINV Off 17 BAr On OPEN PHOT OP BAR 18 ...