12
13
Open clearance
Open clearance
(cm)
3,5
3
2,5
2
1,5
1 (def.)
0,5
0
Dsw8
On
Off
On
Off
On
Off
On
Off
Dsw7
On
On
Off
Off
Off
Off
On
On
Dsw6
On
Off
On
Off
On
Off
On
Off
Dsw5
Off
Off
Off
Off
Off
Off
Off
Off
Dsw4
ON
Dsw3
OFF
Dsw2
OFF
Dsw1
ON
Closed clearance
Closed clearance
(cm)
3,5
3
2,5
2
1,5
1 (def.)
0,5
0
Dsw8
On
Off
On
Off
On
Off
On
Off
Dsw7
On
On
Off
Off
Off
Off
On
On
Dsw6
On
Off
On
Off
On
Off
On
Off
Dsw5
Off
Off
Off
Off
Off
Off
Off
Off
Dsw4
OFF
Dsw3
ON
Dsw2
OFF
Dsw1
ON
First slowdown distance.
First slowdown distance
(cm)
3 - Gates with low inertia
15
30
50 - Gates with high inertia (def.)
Dsw8
Off
On
Off
On
Dsw7
Off
Off
On
On
Dsw6
Off
Off
Off
Off
Dsw5
Off
Off
Off
Off
Dsw4
OFF
Dsw3
ON
Dsw2
ON
Dsw1
ON
Second slowdown distance.
Second slowdown distance
(cm)
12 - Heavy gates (def.)
10
8
6 - Light gates
Dsw8
Off
On
Off
On
Dsw7
Off
Off
On
On
Dsw6
Off
Off
Off
Off
Dsw5
Off
Off
Off
Off
Dsw4
ON
Dsw3
ON
Dsw2
ON
Dsw1
ON
A = First slowdown start distance
B = Second slowdown start distance
C = Total gate stroke
A
A
B
B
C
Speed
Minimum
(def.)
Maximum
Dsw8
Off
On
Off
On
Off
On
On
Off
Dsw7
Off
Off
Off
Off
On
On
On
On
Dsw6
Off
Off
Off
Off
On
On
On
On
Dsw5
Off
Off
Off
Off
Off
Off
Off
Off
Dsw4
OFF
Dsw3
ON
Dsw2
OFF
Dsw1
OFF
Stroke is re-calibrated.
The stroke is usually calibrated when starting up the control unit. Use this function to modify the stroke without having to switch the control unit off
and on.
Re-calibration
Dsw8
Off
Dsw7
Off
Dsw6
Off
Dsw5
Off
Dsw4
Off
Dsw3
Off
Dsw2
Off
Dsw1
Off
Stroke calibration speed.
www.ga
ł
ecki.pl
Содержание RI.624
Страница 34: ...w w w g a e c k i p l...
Страница 35: ...w w w g a e c k i p l...