10
11
Dwell time for automatic closure.
When the
OPEN
input contact closes the countdown is reset. If the
FTC
trips the countdown will be either reset or reduced to 1/4 of the set time
depending on the program mode selected.
Seconds
5
10
15
20
30
40
50
60 (def.)
80
100
120
140
160
180
200
220
Dsw8
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Dsw7
Off
Off
On
On
Off
Off
On
On
Off
Off
On
On
Off
Off
On
On
Dsw6
Off
Off
Off
Off
On
On
On
On
Off
Off
Off
Off
On
On
On
On
Dsw5
Off
Off
Off
Off
Off
Off
Off
Off
On
On
On
On
On
On
On
On
Dsw4
ON
Dsw3
ON
Dsw2
OFF
Dsw1
OFF
Work time.
Seconds
5
10
15
20
30
40
50
60 (def.)
80
100
120
140
160
180
200
220
Dsw8
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Dsw7
Off
Off
On
On
Off
Off
On
On
Off
Off
On
On
Off
Off
On
On
Dsw6
Off
Off
Off
Off
On
On
On
On
Off
Off
Off
Off
On
On
On
On
Dsw5
Off
Off
Off
Off
Off
Off
Off
Off
On
On
On
On
On
On
On
On
Dsw4
ON
Dsw3
ON
Dsw2
OFF
Dsw1
ON
"Pedestrian" opening.
Opening
(cm)
80
95 (def.)
110
120
140
150
170
185
Dsw8
Off
On
Off
On
Off
On
Off
On
Dsw7
Off
Off
On
On
Off
Off
On
On
Dsw6
Off
Off
Off
Off
On
On
On
On
Dsw5
Off
Off
Off
Off
Off
Off
Off
Off
Dsw4
ON
Dsw3
OFF
Dsw2
ON
Dsw1
ON
Speed variation sensitivity.
Variation
%
Disabled
5% (very sensitive)
10% (def.)
15%
20% (little sensitive)
Dsw8
Off
On
Off
On
Off
Dsw7
Off
Off
On
On
Off
Dsw6
Off
Off
Off
Off
On
Dsw5
Off
Off
Off
Off
Off
Dsw4
ON
Dsw3
OFF
Dsw2
ON
Dsw1
OFF
www.ga
ł
ecki.pl
Содержание RI.624
Страница 34: ...w w w g a e c k i p l...
Страница 35: ...w w w g a e c k i p l...