EMERGENCY BATTERY
An optional accessory is available for control unit power supply in case of absence of power.
The kit is made up of a battery charging board and two 12V rechargeable batteries, fixing clamps, screws and wiring.
For further information, refer to the instructions supplied with the accessory.
DIAGNOSTICS
PHOT
SWC1
STOP
SWO1
SWO2
SWC2
PHOT-C
P.P.
PED
One segment of the display is linked to each input. In the event of failure it switches on ac-
cording to the following scheme.
N.C. inputs are represented by the vertical segments. N.O. inputs are represented by the
horizontal segments.
The control unit sees the message AMP1 or AMP2 in case of anti-crushing ammeter sensor
intervention.
ERROR MESSAGES
Some messages that are displayed in case of function anomalies are listed as follows:
Amp1
Obstacle error motor 1/anti-crushing
Check presence of obstacles on motor 1 leaf run
Amp2
Obstacle error motor 2/anti-crushing
Check presence of obstacles on motor 2 leaf run
ENC1
Error, encoder 1/detection of the obstacle
Check the correct connection of motor 1 encoder to the control unit, that
no obstacles are present along the gate stoke and the encoder operates
correctly.
ENC2
Error, encoder 2/detection of the obstacle
Check the correct connection of motor 2 encoder to the control unit, that
no obstacles are present along the gate stoke and the encoder operates
correctly.
Err1
Motor 1 circuit checking error
Check motor 1 connections
Err2
Motor 2 circuit checking error
Check motor 2 connections
Err3
error/fault power circuit
Request technical assistance and eventually replace control unit.
Err4
PHOTO/BAR photocell checking error
Check connections, PHOTO/BAR photocell alignment or presence of ob-
stacles.
Err5
PHOTC photocell checking error
Check connections, PHOTC photocell alignment or presence of obstacles.
Err7
Error active stop (during autoset)
In autoset phase, the STOP input has intervened.
Err8
Error active input (during autoset)
In autoset phase a PP/Open/Close input has intervened.
thrm
Motor thermal protection intervention
Wait for motor cooling, in case reset does not take place, motor replacement
may be necessary
WASTE DISPOSAL
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste disposal and
the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call your installer or a specialised
company.
TECHNICAL DATA
Contol unit supply
24 Vdc
Power supply
230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version
Output supply
1/2 motor 24Vdc
Maximum motor current
2.5+2.5 A
Output supply accessories
24Vdc 500mA max.
Protection level
IP54
Operating temp.
-20°C / +50°C
Radio receiver
built in 433,92 MHz confgurabile (rolling-code or progra rolling-code)
Rolling code transmitters supported
64