![Beninca HEADY 24 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/beninca/heady-24/heady-24_manual_2732854014.webp)
14
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software re-
lease.
TO ACCESS PROGRAMMING:
1 – Press the button <PG>, the display goes to the first menu, Parameters “PAR”.
2 – With the <+> or <-> button, select the menu you want (PAR>LOG>RAD>NMAN>MACI>RES>AUTO>CODE).
3- Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal “PRG” which indicates that programming has been completed.
NOTES:
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any changes.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 120s the control unit quits programming mode and switches off the display.
When the board is switched on, the software version is displayed for around 5 sec
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
The tables below describe the individual functions available in the control unit.
PARAMETERS (
PAR
)
MENU
FUNCTION
MIN-MAX-(Default)
MEMO
TCA
Automatic closing time. Active only with logic “TCA”=ON.
At the end of the set time the control unit orders a closing manoeuvre.
1-240-(40s)
TM1
Operating time, motor 1. The operating time is adjusted at normal speed during motor
1 opening and closing phases. See Paragraph “Adjustment of the gate leaf speed”.
By setting the value to 0, the operation is performed with around 2 seconds of pick-up
and then the movement is carried on at reduced speed for the entire stroke.
0-99-(5s)
TM2
Operating time, motor 2. The operating time is adjusted at normal speed during motor
2 opening and closing phases. See Paragraph “Adjustment of the gate leaf speed”.
By setting the value to 0, the operation is performed with around 2 seconds of pick-up
and then the movement is carried on at reduced speed for the entire stroke.
0-99-(5s)
PMo1
The anti-crash device* (amperometric sensor) operation is adjusted in the opening
phase, at normal speed - Motor 1.
1-99-(20%)**
PMC1
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
phase, at normal speed - Motor 1.
1-99-(20%)**
PMo2
The anti-crash device* (amperometric sensor) operation is adjusted in the opening
phase, at normal speed - Motor 2.
1-99-(20%)**
PMc2
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
phase, at normal speed - Motor 2.
1-99-(20%)**
TDMo
Mot.2 opening delay time.
Regulates the delay time of motor 2 on opening with respect to motor 1
0-15-(2s)
TDMC
Mot.1 closing delay time
Regulates the delay time of motor 1 on closing with respect to motor 2
0-40-(3s)
SLD1
Adjusts motor 1 speed during slowing phases. Value expressed in percentage of
normal functioning speed.
30-70 (50%)
SLD2
Adjusts motor 2 speed during slowing phases. Value expressed in percentage of
normal functioning speed.
30-70 (50%)
SpD1
Adjusts motor 1 speed during normal speed phase.
Value expressed in percentage.
30-99 (99%)
SpD2
Adjusts motor 2 speed during normal speed phase.
Value expressed in percentage.
30-99 (99%)
Pso1
The anti-crash device* (amperometric sensor) operation is adjusted in the opening
phase, at reduced speed - Motor 1.
1-99-(20%)**
Psc1
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
phase, at reduced speed - Motor 1.
1-99-(20%)**
Pso2
The anti-crash device* (amperometric sensor) operation is adjusted in the opening
phase, at reduced speed - Motor 2.
1-99-(20%)**
Psc2
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
phase, at reduced speed - Motor 2.
1-99-(20%)**
SeaU
The intervention threshold of the anti-crashing device (Encoder) during the phase at
normal speed is adjusted.*
0:Off-1:minimum sensitivity - 99: maximum sensitivity
0-99-(0%)