Beninca CP.BULL OMI Скачать руководство пользователя страница 10

30

4) TO ACCESS PROGRAMMING

1 – Press the button <PG>, the display goes to the first menu, Parameters “PAR”. 
2 – With the <+> or <-> button, select the menu you want.
3 – Press the button <PG>, the display shows the first function available on the menu.
4 – With the <+> or <-> button, select the function you want.
5 – Press the button <PG>, the display shows the value currently set for the function selected.
6 – With the <+> or <-> button, select the value you intend to assign to the function.
7 – Press the button <PG>, the display shows the signal “PRG” which indicates that programming has been completed.

12.1) RUN SELF-LEARNING AND ANTI-CRUSHING DEVICE SETTING 

When operator assembly and wiring is completed, parameters and logic are programmed, self learning allows the operator to learn the 
stroke and torque.
Enter menu Auto and press the button < PGM >, PUSH will be displayed. 
Press again the button < PGM >: self-learning is beginning: PRG will be displayed, and the control panel completes some opening/
closing cycles. 
When the procedure is completed OK will be displayed. 
This procedure can be followed from any position of the gate/door leaf and can be stopped at any moment by pressing keys <+> and 
<-> at the same time, or through the activation of STOP/PHO/PHA/DAS/PP/PED inputs.
If the procedure is not successful, the wording ERR appears. Check that no obstacles or frictions are present.
After the AUTOSET procedure it is necessary to check the value of the operating forces according to the European Standards EN12445 
and EN12453. If the value of the force is too high it is mandatory to install a safety edge which complies to the standard EN12978.

Notes: 

Pressing <-> with the display turned off means an impulse of P.P. 
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any chang-
es. 
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.

5) PARAMETERS, LOGIC AND SPECIAL FUNCTIONS 

The tables below describe the individual functions available in the control unit.

PARAMETERS (

PAR

MENU

FUNCTION

MIN-MAX-(Default)

MEMO

TCA

Automatic closure time. It is activated only with “TCA” logics :ON

At the end of the preset time, the control unit starts a new closing operation.

1-240-(40s) 

Tped

The passage left open by the door/gate leaf during the partial opening controlled 

by the pedestrian inoput, is adjusted. 

The value is expressed in percentage on the aggregate value of the stroke.

5-100-(20%)

tsmO

Braking during OPENING is adjusted. 

The value is expressed in percentage on the aggregate value of the stroke.

See section “Speed and slowdown settings”*.

10-100-(20%)

tsmc

Braking during CLOSURE is adjusted. 

The value is expressed in percentage on the aggregate value of the stroke.

See section “Speed and slowdown settings”*.

10-100-(20%)

FSTo

The OPENING speed is adjusted.

IMPORTANT: Change the values of this parameter only by keeping to the 

weight limits shown in Table 1.

See section “How to adjust speed and braking”.

20-120-(45)

FSTc

The  CLOSURE speed is adjusted.

IMPORTANT: Change the values of this parameter only by keeping to the 

weight limits shown in Table 1.

See section “How to adjust speed and braking”.

20-120-(45)

sldo

Adjusts the slowdown speed during the opening phase.
See section “Speed and slowdown settings”*.

10-40-(25)

sldc

Adjusts the slowdown speed during the closing phase.
See section “Speed and slowdown settings”*.

10-40-(25)

PMO

The torque applied to motor 2 in the opening* phase is adjusted.

1-99-(70%)

PMC

The torque applied to motor 2 in the closing* phase is adjusted.

1-99-(70%)

sEav

The trigger time of the anti-crash device (Amperometric) is adjusted during the 
normal speed phase*. 
0:Off-99: maximum sensibility - 1: minimum sensitivity

0-90-(1%)

Содержание CP.BULL OMI

Страница 1: ...D R A F T CP BULL OMI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI IT EN...

Страница 2: ......

Страница 3: ...S II Ch Radio L N GND GND Shield N L SCA SERVICE LIGHT 24 Vdc 0 5A BRAKE RESISTOR PHOTO TEST fig 15 OPEN CLOSE JP1 BAR Open DAS N C JP1 BAR Close DAS 8K2 U1 LD1 LD2 MOT MOT COM 15AT 250Vac 5A P3 J6 J8...

Страница 4: ...NC NO RX1 TX1 24 Vdc PHOTO COM PHOTO TEST PHOTOTEST OPEN PHOTOTEST CLOSE OPEN OPEN LOG MINV OFF LOG MINV ON OPEN OPEN LOG MINV OFF LOG MINV ON 17 SCA 24Vac AUX 0 Aux 1 L N Service Light 230V SCA 24V M...

Страница 5: ...5 OPEN Open Safety Edge COM PHOTO Close Safety Edge 8K2 N O Jumper DAS DAS MOTOR JP1 Open DAS N C JP1 Close DAS 8K2 N C 19 bar On BAR LOGIC ON...

Страница 6: ...PRG PRG PRG tca ped tsmo tsmc tm fstc sldo sldc pMo pmc seav 40 20 20 20 240 fsto 45 25 25 70 70 1 sear 1 blo 3 45 PAR PAR Power ON Display OFF Firmware Ver 3s Diagnostic LOG tca IBL IBCA SCL PP PRE h...

Страница 7: ...G dr cken Appuyez sur la touche PG Presionar la tecla PG Wcisn przycisk PG Selezionare il pulsante del trasmettitore da associare alla funzione Press the transmitter key which is to be assigned to fun...

Страница 8: ...nd EN 12453 Only use original accessories and spare parts use of non original spare parts will cause the warranty planned to cover the products to become null and void All the mechanical and electrica...

Страница 9: ...EDGE SAFETY EDGE Input Resistive Edge 8K2 JP1 DAS close Mechanical Edge N C JP1 DAS OPEN The activation of the Safety Edge stops and reverses the movement of the leaf for 3s RADIO RADIO RECEIVER Plug...

Страница 10: ...making any chang es Hold down the key or the key to accelerate the increase decrease of the values After waiting 30s the control unit quits programming mode and switches off the display 5 PARAMETERS...

Страница 11: ...X It selects the operating mode of the SCA output 0 SCA 1 Service light The contact closes for the time preset with TLS parameter The countdown starts at the inception of the opening operation 2 Area...

Страница 12: ...cm The safety edge connected to the DAS input is enabled only during the CLOSING PHASE Off The intervention of the safety edge connected to the DAS input stops and reverses the movement of the leaf f...

Страница 13: ...ode must be typed in IMPORTANT TAKE NOTE of the protection code and KEEP IT IN A SAFE PLACE for future maintenance operations To remove the code from a protected control unit enter the programming mod...

Страница 14: ...adjustable though the value TBR and it must respect the values indicated on the Table 1 IMPORTANT For the correct operation of parameters it is mandatory that the AUTOSET be carried out correctly see...

Страница 15: ...lt or error in the setting err AUTOSET ERROR If the error shows up during the stroke learning phase check the status of the inputs PP STOP PED PHOTO PHOTC DAS OPEN CLOSE and check also that the leaf r...

Отзывы: