Manual control of the air-conditioning
1. Data display
Screen which displays the desired temperature, the programmed values and the error messages.
2. MODE
Enables you to navigate between the different operating modes.
3. POWER/OFF
Comes on when the system is switched off. The manual ventilator may continue to run.
4. COOL
Indicates that the compressor is activated when cooling.
5. HEAT
Indicates that the compressor is activated when heating.
6. Option (Auxiliary heating).
7. AUTOMATIC
Comes on when the system is in AUTO mode.
8. DEHUMIDIFY
Comes on when the system is in dehumidifying mode.
9. Keys + and -
Allow you to raise or lower the desired temperature.
10. Cooling indicator
This indicates that the compressor is in COOLING mode.
11. Heating indicator
This indicates that the compressor is in HEATING mode.
12. Option (Auxiliary heating).
13. temperature control indicator
This indicates the temperature control adjustment (the desired ambient temperature).
14. Indicator for the manual ventilator
This comes on when the manual ventilator is running.
15. Indicator for the automatic ventilator
This comes on when the ventilator is running in automatic mode.
16. Ventilator key
Allows you to select manual or automatic mode for the ventilator.
17. Ventilator speed indicator
Shows the ventilator speed.
NOTES
- When the system is programmed in
dehumidifying mode, the system's safety
devices remain active: if there is an interruption
in the flow of sea water or a drop in AC voltage,
the system automatically stops.
- In cooling mode, the system works efficiently
when the sea water temperature is below 30
degree C.
- In heating mode, the system works efficiently
when the sea water temperature is above 13
degree C.
- It is important to switch the system to
HEATING mode at least once a month, to
prevent the crossover cock becoming stuck in
COOLING mode.
Onbo
ard co
mfor
t
11
11
Содержание ANTARES 36
Страница 1: ...197855 RCD 2 Index B ANTARES 36 OWNER S MANUAL ...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 12: ......
Страница 13: ...13 DESIGN CATEGORIES AND DISPLACEMENT Design categories 16 2 ...
Страница 17: ...17 STABILITY AND BUOYANCY Stability data 18 Access to the boat 19 3 ...
Страница 20: ...20 197855 RCD 2 Index B Access to the engine compartment Saloon Aft cabin Stability and buoyancy ...
Страница 21: ...197855 RCD 2 Index B 21 Access to the flybridge Direct access to cockpit locker Stability and buoyancy 3 ...
Страница 22: ...22 197855 RCD 2 Index B Access to the saloon Stability and buoyancy ...
Страница 23: ...23 MANOEUVRABILITY Visibility from the steering station 25 4 ...
Страница 50: ......
Страница 61: ...197855 RCD 2 Index B 61 7 2 7 Layout of the deck wiring looms DC circuit 3 L L F F Electrical system 7 ...
Страница 82: ......
Страница 83: ...83 DOMESTIC APPLIANCES Fridge Cooler 84 Hot plate 86 9 ...
Страница 87: ...87 AUDIO VISUAL EQUIPMENT Television 88 Hifi 89 10 10 ...
Страница 90: ......
Страница 108: ......
Страница 113: ...197855 RCD 2 Index B 113 Water tank Location Aft cabin Gauge Location Passageway Water systems 12 12 ...
Страница 128: ......
Страница 137: ...197855 RCD 2 Index B 137 13 7 ENGINE INSTALLATION 26 12 01 02 03 07 21 22 23 24 27 29 Engine 13 13 ...
Страница 138: ...138 197855 RCD 2 Index B 19 28 14 17 18 20 09 09 13 15 16 16 06 Engine ...
Страница 142: ...142 197855 RCD 2 Index B DIAGRAM OF THE LAYOUT Engine ...
Страница 146: ......
Страница 147: ...147 STEERING SYSTEM General points 148 Layout diagram 149 Hydraulic steering 151 Bow thruster 152 14 14 ...
Страница 149: ...197855 RCD 2 Index B 149 14 2 LAYOUT DIAGRAM Steering system 14 14 ...
Страница 154: ......
Страница 166: ......
Страница 167: ...167 HULL FITTINGS Upholstery 168 Interior woodwork 171 Interior maintenance 171 16 16 ...
Страница 172: ......
Страница 179: ...179 ENVIRONMENT Waste management 180 ...
Страница 181: ...181 APPENDIXE Meaning of the labels 182 ...
Страница 184: ......