36
TROUBLESHOOTING.
Failure:
Plug in power supply unit – RESET – plug in motor cable completely – plug in manual cable completely – disconnect system for a moment – RESET – request
Service personnel – replace power supply unit.
Keystroke causes nothing but a beep:
RESET – disconnect system – RESET – plug in motor cable completely – RESET – request Service personnel
Manual switch indicates “E”:
RESET – disconnect system – RESET – request Service personnel – replace manual control switch
Table in skewed position after shutdown:
Remove overload – RESET – disconnect system – RESET – request Service personnel – replace control mechanism
Table in skewed position after several runs:
Remove overload – disconnect system – RESET – request Service personnel
Table moves approx. 5 cm into opposite direction during run:
Remove obstacle – request Service personnel
One column fails to run during RESET, complete failure thereafter:
Plug in motor cable completely – RESET – request Service personnel
Note:
Please continue troubleshooting operation if system still fails to operate after manual RESET (see page 11).