15
WEEKLY MAINTENANCE
1. Lubricate all rollers with general purpose oil or
WD-40.
2. Check all Hose connections, bolts and pins to insure
proper
mounting.
3. Lubricate Safety lock pivot points with general
purpose oil or WD-40.
4. Check and tighten Cylinder Bolt. (See Fig. 7.4)
MONTHLY MAINTENANCE
1. Lubricate the Cylinder Pin and Main Hinge Pin with
all purpose grease using a needle point lube coupler.
(See Fig. 7.5 & 7.6)
2. Check Safety Locks to insure they are in good
operating
condition.
3. Make a visual inspection of
ALL MOVING PARTS
and check for excessive signs of wear.
4. Replace
ALL FAULTY PARTS
before lift is put back
into
operation.
NEVER EXCEED THE RATED CAPACITY
of lift.
DO NOT USE LIFT
if any component is found to be
defective or worn.
NEVER OPERATE LIFT
with any person or
equipment
below.
ALWAYS STAND CLEAR
of lift when lowering or
raising.
ALWAYS INSURE SAFETY LOCKS ARE
ENGAGED
before entering work area.
NEVER LEAVE LIFT IN ELEVATED CONDITION
unless all four safety locks are engaged.
Fig. 7.4
Fig. 7.5
Fig. 7.6