KGX 150/130 Transceivers and Receivers
D201405000060
REV 0
Oct 2014
2-9
KGX Control Panel
Honeywell International Inc. Do not copy without express permission of Honeywell.
Possible system messages are shown in Table 2--2. When multiple
messages are present, the page will automatically scroll through the
messages. Push
FN
again to exit this mode and return to normal
operation.
Table 2--2
System Messages
KGX Control Panel
Display Message
Description
Synth Unlock
Transceiver Diagnostic -- Timing fault
Tx Fault
UAT Transceiver fault
Tx Power Low
UAT Transceiver power low during
transmit
Tx PSU High
UAT Transceiver power supply output too
high
Tx PSU Low
UAT Transceiver power supply output too
low
Squitter Fail
System Diagnostic
Remote Hot
KGX 150T/130T internal temperature too
high
No ADS--B Pos
GPS position not acquired or satellite
tracking lost
GPS Fault
GPS has reported a fault or not
responding
Top ant Fault
Top antenna is disconnected
Bot ant Fault
Bottom antenna is disconnected
PSU Fail
Internal DC power supply failure
ADC Fault
ADC or Altitude sensor fault or not
responding
NOTE:
Troubleshooting:
1. Note the message shown.
2. Cycle power to the KGX using the Mode Control knob on
the KGX control panel.
3. If the message persists contact an authorized BendixKing
service center.