7.4 Unit Installation
Install unit in the tray using the captive 3/32” Hex screw. Verify the connectors are fully engaged prior
to powering on the unit.
7.5 Configuration
The AeroNav XXX can be configured in the aircraft. This section will describe the procedures for
configuring the AeroNav XXX.
Configuration consists of setting up communication protocols in Maintenance Mode, designating
specific types of equipment to be integrated and setting up system settings.
Configuration also consists of setting up User Options preferences in non-Maintenance Mode via the
SYS tab of the AUX page.
For new installations, use this section to configure the AeroNav XXX for the specific airplane.
For replacement installations in which the AeroNav XXX is replacing a GNS 530/W or GNS 430/W, use
Appendix F: Configuration Setup of this manual to first record the configuration of the GNS530/W or
GNS430/W that is being replaced by the AeroNav XXX and then using that recorded data, use the
AeroNav XXX Maintenance Mode pages as defined in this section and Appendix F: Configuration
Setup to properly set up and record configurations.
7.5.1 Maintenance Mode
The Maintenance Mode can be accessed by using the following procedures (on the ground only):
1.
Power on the AeroNav XXX
2.
Acknowledge all start up screens by pressing “Enter”
3.
Press Proceed Line Select Key (LSK) followed by the Confirm LSK on the database
acknowledgement screen (if shown)
4.
Select the “AUX” function key to display the Auxiliary Page. Press on the right side of the
“AUX” Function key until the “SYS” tab is shown
5.
Select “Status/Software” LSK by pressing associated button until “Update Databases”
appears. (If shown)
6.
Select “Update Databases” LSK by pressing the associated button. Press the “Confirm” LSK
after it appears. The screen will blank for several seconds before coming up in Maintenance
Mode
Please note: