89000046-014
KSN 780/8XX/900 AeroNav AML STC Installation Manual for Helicopters
Rev 0
Page 7-39
© Honeywell International Inc. Do not copy without express permission of Honeywell.
b.
To increment the value of the “Roll Angle” use the left inner knob to select a “Tilt
Setting” between 5 and 10. When the “Tilt Setting” is between 5 and 10, the value of
the “Roll Angle” field will slowly increase.
c.
To decrement the value of the “Roll Angle” use the left inner knob to select a “Tilt
Setting” between -5 and -10. When the “Tilt Setting” is between -5 and -10, the value of
the “Roll Angle” field will slowly decrease.
d.
When the desired setting is reached, quickly adjust the “Tilt Setting” to above 10 or
below -10 to “lock in” the setting.
8.
To save the changes into the radar perform the following steps:
a.
Set the Knob-Func LSK to ‘Gain’ and rotate the left outer knob to obtain a “Gain Pot”
setting between -4 and -5.
b.
The “Faults” field shall display “Gyro Input”.
c.
Set the Knob-Func LSK to ‘Tilt’ then change the “Tilt Setting” to -15.00°. The “Faults”
field shall flash indicating that the calibrations settings have been saved. If the save
procedure is successful the “Gyro Input” fault will be removed and the “Scan Angle” will
cycle through the entire number range. A “transmitter inhibit” fault shall be displayed in
the “Faults” field.
7.5.18 Stormscope Test Page
The Maintenance Mode Stormscope Test page is accessible from the Maintenance Mode Config Tab
when one set of the RS232 ports has been configured as WX-500 and at least one power cycle has
been executed since configuration.
Stormscope Test page contains the following LSKs: Change Mode, Strikes Clear, Get Data
Change Mode LSK
- Changes to the Stormscope test mode as shown in the LSK. The mode selected
will be returned by the WX-500 and will display within the strike display. Repeated presses of the
Change Mode LSK will step through each of the modes, cycling back to the first mode in the list
(Weather).
These are the Stormscope test modes:
•
Weather - basically a fixed heading version of normal flight mode - will display real lightning
strikes if any are generated.
•
Noise - similar to Weather mode but with the WX-500 sensitivity set to determine where
excess noise might be generated.
•
Strike Test - a target displaying test strikes as generated by a WX-500 strike generating test
set.
•
Demo - similar to Weather mode with the strikes generated internally by the WX-500's
Demo mode.
•
Self-Test - executes the WX-500 internal Self-Test sequence which will return to Weather
mode after 10 seconds.
Strikes Clear LSK
- Pressing this LSK will send a "clear strikes" command to the WX-500, clearing its
internal buffer of strikes.
Get Data LSK -
Pressing the Get Data LSK will Download Data from the WX-500. The Stormscope
Downloadable Data page will display ASCII data as retrieved verbatim from the Stormscope.
Repeated presses of the Get Data LSK will step through each of the Downloadable Data modes,
cycling back to the first mode in the list (SW Version).
These are the Stormscope Downloadable Data modes: