3-6
Symptom Isolation Procedures
Side Sensor Not Detecting Targets
Step A
Procedure
Condition
Action
Step B
Procedure
Condition
Action
Step V
Procedure
Condition
Action
1. Clear area around sensor of
objects.
2. Key on.
3. Allow Operator Display
Unit to go through self-
test and shows no
targets (yellow LED
light should be on).
1. Key on.
2. Place a target 3 to 10
feet directly in front of
the Sensor.
1. Key off.
2. Reconnect all connectors.
3. Drive vehicle to
determine if problem
has been corrected.
If both LED lights turn on
for .5 seconds – followed by
red LED for 5 seconds –
followed by a continuous
yellow light
If only the yellow LED light
turns on for .5 seconds,
followed by a continuous
yellow light
If both LED lights turn on
for .5 seconds, followed by
continuous yellow and red
lights
If the Operator Display Unit
indicates that a target is
detected (red light on)
If the Operator Display Unit
does not indicate a target is
present (yellow light on)
If complaint has been
repaired
If complaint has not
been repaired
Go to
Step B
.
Replace Operator Display Unit.
Go to the “Power-Up Sequence
Test” on page 2-4.
Go to
Step V
.
Replace sensor.
Test complete.
Return to
Step A
to fi nd
error in testing.