CC612(4G)_D00325_06_M_XXEN/09.2021 27
CC612 charge controller
• The
State
tab of the charging system control interface can be accessed via the URL
http://192.168.123.123. It only provides status information.
• The
Operator
tab of the charging system control interface can be accessed via the URL
http://192.168.123.123/operator. As well as showing status information, operator parameters can
be set. To access this tab, user name and password are required:
– User name: operator
– Password: yellow_zone
• The
Manufacturer
tab of the charging system control interface can be accessed via the URL
http://192.168.123.123/manufacturer. As well as showing status information, operator and manu-
facturer parameters can
• be set. To access this tab, user name and password are required:
– User name: manufacturer
– Password: orange_zone
These default passwords can be changed. The manufacturer can also change the user passwords and opera-
ting parameters.
i
The URL for the Manufacturer tab should not be shared with the operator.
The
State, Operator and Manufacturer
tabs each have an identical
Settings
tab and a
Documentation
tab.
On the Settings tab, all Backend relevant information, supplied by the Backend provider, can be entered in-
cluding:
•
OCPP Mode
(e.g. OCPP-B 1.5, OCPP-J 1.6)
•
SOAP OCPP URL
of Backend (i.e. the HTTP URL of the OCPP backend system)
•
Hostname (Binary OCPP)
- The DNS hostname or IP address of the binary OCPP proxy server for
the Backend system
•
Portnumber (Binary OCPP)
- TCP port of the proxy server for binary OCPP communication with
the Backend system
•
Websockets JSON OCPP URL
of the Backend - Only used if OCP-J 1.6 mode is selected
The Documentation tab contains:
• Information concerning OCPP status notification error messages (e.g. codes, activation and resolu-
tion messages, notes and corrective actions)
• OCPP configuration keys for OCPP 1.5 and 1.6 (e.g key name and description))
Application of changed parameters
Parameter changes are not necessarily applied after submission. To submit all changed parameters, click the
"Save & Restart" button at the bottom of the tab. A message indicating a necessary restart may appear.
5.1.1.1 Periodicle reboot of the charge controller
As part of the normal periodicle reboot, the charge controller carries out system resets to recover from situati-
ons in which connectivity with the backend system cannot be obtained and no vehicle is currently charging.
This behaviour is intentional and serves to ensure that the charge controller recovers from as many situations
as possible without intervention. In a situation in which no SIM card is inserted or the configuration does not
yet match the SIM card, a system reset can be easily mistaken for erroneous behaviour.
i
After the web configuration interface has been accessed or while a vehicle is connected, the charging point
will suppress system reboots for at least 2 minutes to allow all parameters to be configured.