CC612(4G)_D00325_06_M_XXEN/09.2021 21
CC612 charge controller
4.2.1.10 Connection to lock release modules
i
When using the Mennekes Actuator Control Type 30537-A, the full force is not available for the locking and
unlocking process.
The following legend refers to the corresponding connection examples:
A
Connection A of the charge controller
1, 2, 3
Wire
M
Aktuator
Each type 2 socket can also be used in conjunction with lock release modules from various manufacturers. A
typical wiring diagram illustrating the connection between the charge controller, a Mennekes/Bals/Walther
Werke/Harting socket actuator and a lock release module (EM-EV-CLR-12V) from Phoenix Contact is shown be-
low:
-
EV Charge
Lock Release
POWER ERROR
-IN +OUT-OUT
OUT
+
IN
12V GND +IN
3
1
2
M
-
+
CP PP
L1
L2
L3
N
PE
AC
A
DC