Bender CC612 Скачать руководство пользователя страница 1

Manual EN

CC612(4G)_D00325_06_M_XXEN/09.2021

CC612 charge controller

Charge controller for electric vehicle charging stations, wallboxes or 
street light charging points

Содержание CC612

Страница 1: ...Manual EN CC612 4G _D00325_06_M_XXEN 09 2021 CC612 charge controller Charge controller for electric vehicle charging stations wallboxes or street light charging points...

Страница 2: ...3 cents 30 sec remaining time 6 3 cents min Mobile phone higher depending on mobile phone tariff Repair service Repair calibration and replacement service Londorfer Strasse 65 35305 Gr nberg Germany T...

Страница 3: ...3 2 2 Charging system with a type 2 socket and an intermediate relay 13 4 Connection 16 4 1 Connection conditions 16 4 2 Connectivity 17 4 2 1 Master slave connection 18 4 2 1 1 Micro USB configurati...

Страница 4: ...of the charge controller to the backend 28 5 1 6 2 via GSM 4G modem 29 5 1 6 3 via USB Ethernet Adapter oder USB WLAN USB 1 29 5 1 7 eHZ Modbus S0 meter connectivity 30 5 1 8 Plug locking and unlockin...

Страница 5: ...low level risk that can result in minor or moderate injury or damage to property if not avoided i Information can help to optimise the use of the product 1 2 1 Signs and symbols Disposal Temperature...

Страница 6: ...eure Mounting and installation with device combinations not recommended by the manufacturer This operating manual and the enclosed safety instructions must be observed by all persons working with the...

Страница 7: ...iant with JSON SOAP and Binary implementation Supported mobile networks 4G LTE 3G UMTS and 2G GSM with an integrated 4G modem 2 USB interfaces 1 CONFIG for local configuration Extension port for perip...

Страница 8: ...charge controller Alternatively any meter with an S0 interface can be attached to one of the available inputs A 12 V power supply is needed to operate the charge controller and an RFID module can be u...

Страница 9: ...he charging current to the configured value if it is ex ceeded The second threshold will suspend charging i The temperature measurement is an estimation based on temperature sensors positioned on the...

Страница 10: ...nd mounting 3 Dimensions and mounting 3 1 Dimensions Abb 3 1 Note Dimensions in mm acc to ISO 2768 m Dimensions incl antenna socket 3 2 Mounting i DIN rail mounting Example view 3 2 1 Charging system...

Страница 11: ...A CP PP PE N L1 L2 L3 e L1 L2 L3 N PE PP CP PE L1 N L3 L2 f 12V 0V 11 14 B 1 2 3 4 5 6 D C OUT IN A RJ10 F RJ45 E CC612 ALARM READY PLC USB 1 SIM CONFIG B A PP IN1 IN2 21 IN1 IN2 CP 24 C IN2 IN2 n IN1...

Страница 12: ...type 1 or type 2 plug Legend A Connection locking engine d Contactor B Connection socket User Interface e Type 2 socket C Connection socket f Type 2 plug D Connection CurrentTransformer CT g Connecti...

Страница 13: ...mediate relay Wiring diagram IN M A CP PP PE N L1 L2 L3 e L1 L2 L3 N PE k PP CP PE L1 N L3 L2 f PP IN1 IN2 21 IN1 IN2 CP 24 C IN2 IN2 n IN1 IN1 m 21 24 j PP CP g h 12V 0V 11 14 B 1 2 3 4 5 6 D C OUT I...

Страница 14: ...Proximity Pilot E Connection User Interface RJ45 h Connection Control Pilot F Connection Modbus eHZ meter RJ10 i Relay 1 Control pin contactor a RCDType A j Output relay 2 b Voltage supply DC 12V k I...

Страница 15: ...743211000 Harting Wire 3 Wire 1 Wire 2 Walther Werke Eco Slim 32 A 9743205180 with connection cable 790000001 Wire 1 black Wire 3 blue Wire 2 red Phoenix Contact 1405213 1405214 1405215 1405216 140817...

Страница 16: ...nals with care I The RJ45 user interface is not intended as an Ethernet interface i Information Connect PE to 0V reference level for Control Pilot CP communication must be at same level as the power s...

Страница 17: ...riants A Front view Data gateway with modem B Front view Data gateway without modem C Bottom D Top Variant with eHz meter E Top Variant with Modbus meter 2 CC612 ALARM READY PLC USB 1 SIM CONFIG 3 1 4...

Страница 18: ...page 24 Currently one DLM Slave can connect to the DLM Master The communication protocol is binary OCPP 1 6 Essentially the Master controller becomes the OCPP backend for the DLM Slave The DLM Master...

Страница 19: ...sed to indicate An error has occurred ALARM Online connectivity to a backend system READY Powerline Communication PLC acc to ISO 15118 This LED is not shown on the front panel of variants which do not...

Страница 20: ...ault current detection in an AC charging system an integrated residual direct current monitoring module RDC M is used This module uses an external magnetically shielded measuring current transformer T...

Страница 21: ...n examples A Connection A of the charge controller 1 2 3 Wire M Aktuator Each type 2 socket can also be used in conjunction with lock release modules from various manufacturers A typical wiring diagra...

Страница 22: ...th Mennekes lock release module Socket actuator Walther Werke Eco Slim 32 A 9743205180 with Phoenix Contact lock release module OUT IN 1 3 2 Mennekes Actuator Control Typ 30537 A M CP PP L1 L2 L3 N PE...

Страница 23: ...V CLR 12V from Phoenix Contact is shown below A typical wiring diagram illustrating the connection between the charge controller a Mennekes socket actua tor and a lock release module from Mennekes is...

Страница 24: ...ncreasing energy amounts reported If meter readings are required the baud rate and the slave ID need to be configured direct ly on the Modbus meter as follows Baud rate 9 600 Bd Slave ID 1 8N1 8 data...

Страница 25: ...web interface Connection to the mobile network and subsequently the backend system usually lasts between 6 to 48 hours after which the connection may be terminated by the mobile net work The charging...

Страница 26: ...ller USB configuration interface CONFIG emulates a Remote Network Driver Interface Specification RNDIS network when it is plugged into Windows Linux or Mac OS computers In a Linux and Mac OS this virt...

Страница 27: ...DNS hostname or IP address of the binary OCPP proxy server for the Backend system Portnumber Binary OCPP TCP port of the proxy server for binary OCPP communication with the Backend system Websockets J...

Страница 28: ...eters of the manufacturer configuration to default Click the Factory Reset Restart button to reset the charge controller to factory settings 5 1 4 Testing After completing the configuration the charge...

Страница 29: ...onnection may then be terminated by the mobile network The charging system detects the discon nection and automatically reconnects During reconnection the STATUS LED on the charge controller front pan...

Страница 30: ...tically unlocks the socket outlet of the charging system allowing the cable to be removed 5 1 9 Authorisation and charging The charging process can be initiated by holding an RFID card registered with...

Страница 31: ...ds to be manually selected To do this Open the device manager from the control panel Right click the RNDIS Ethernet Gadget menu item located under Other devices and select Update Driver Software Selec...

Страница 32: ...esidual current tripping Patents EP 2 571 128 US 9 397 494 ZL 201210157968 6 CN 103001175 EP 2 813 856 Wireless parameters Optional for data gateways with 4G modem only Frequency bands 800 MHz 850 MHz...

Страница 33: ...er Meter interface User interface User interface RJ45 Max cable length to RFID module 3 m Switching elements Relay 1 configurable Relay 2 charging contactor Switching elements 2 x 1 N O contacts Opera...

Страница 34: ...nection type terminal block A and B push wire terminal Connection specifications rigid flexible 0 2 2 5 mm AWG 24 12 flexible with ferrule without plastic sleeve 0 25 2 5 mm AWG 24 14 flexible with fe...

Страница 35: ...llowing European directives Richtlinien 2011 65 EU RoHS Richtlinie RoHS directive Directives 2014 53 EU RED Richtlinie RED directive Zur Beurteilung der Konformit t wurden folgende Normen herangezogen...

Страница 36: ...t current monitoring module RDC M only works in combination with the measuring current transformer to be ordered separately Different cable lengths are available Accessories Art No Manual No RFID114 w...

Страница 37: ...from soft ware version State Changes 10 2019 05 06 2021 06 Added Chapter 2 3 1 Chapter 4 2 1 8 Residual direct current monitoring modulel RDC M Changed Content to IEC 62955 new layout all graphics De...

Страница 38: ...38 CC612 4G _D00325_06_M_XXEN 09 2021...

Страница 39: ...CC612 4G _D00325_06_M_XXEN 09 2021 39 CC612 charge controller...

Страница 40: ...de www bender de All rights reserved Reprinting and duplicating only with permission of the publisher Bender GmbH Co KG PO Box 1161 35301 Gr nberg Germany Londorfer Str 65 35305 Gr nberg Germany Tel 4...

Отзывы: