20
5. GENERATOR USE
WARNING!
Do not connect directly to the building’s electrical system. Doing
so may result in electrical shocks, fire, and backfeeding the grid.
Connections for standby power to a building’s electrical system
must
be done by a qualified electrician and must comply with all
applicable laws and electrical codes. See Chapter 1.2 - Safety for
more information.
Before using the generator, consult a local electrician and local
electrical codes to determine grounding requirements for your
intended use. This generator is floating neutral.
Use only grounded 3-prong extension cords in good condition,
ensure the wire size is sufficient to safely carry the generator’s
wattage. See Chapter 1.2 - Safety for more information.
5.1 OUTPUT, OVERLOAD, AND OIL ALERT INDICATOR
Light (Solid)
Description
Green
Output Indicator
ON
Indicates normal operation
OFF
Indicates a problem or unit is off
Red
Overload Indicator
ON
Indicates overload or problem with
connected appliances, disconnect any
appliances.
OFF
Indicates normal operation
Red
Low Oil Indicator
ON
Indicates insufficient oil in the
crankcase
OFF
Indicates normal operation
Low Oil
Huile bas
Overload
Surcharge
Ready to Use
Pret a utiliser
Содержание BG4500i
Страница 1: ...BG4500i MANUAL TM...
Страница 54: ...BG4500i TM MC TM MC...
Страница 55: ...BG4500i MC MANUEL...
Страница 110: ...BG4500i TM MC TM MC...